2013
DOI: 10.1097/prs.0b013e31828bd6b0
|View full text |Cite
|
Sign up to set email alerts
|

Prosthetically Guided Maxillofacial Surgery

Abstract: Therapeutic, III.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
48
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 103 publications
(50 citation statements)
references
References 9 publications
2
48
0
Order By: Relevance
“…Ti6Al4V) were used in all cases due to their suitable physical and mechanical properties: low specific weight, corrosion resistance and good biocompatibility 96 . 3DP reconstruction plates, tray and meshes were associated with a bone autograft in 9 studies: 66.6% opted for a fibula free flap 77 78 94 96-98 and 33.3% for an iliac crest free flap 68 113 128 . Differently, Lee et al made use of a mandibular implant without the support of a bone autograft, proving an acceptable alternative in cases of unsuitable free flap surgery 70 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Ti6Al4V) were used in all cases due to their suitable physical and mechanical properties: low specific weight, corrosion resistance and good biocompatibility 96 . 3DP reconstruction plates, tray and meshes were associated with a bone autograft in 9 studies: 66.6% opted for a fibula free flap 77 78 94 96-98 and 33.3% for an iliac crest free flap 68 113 128 . Differently, Lee et al made use of a mandibular implant without the support of a bone autograft, proving an acceptable alternative in cases of unsuitable free flap surgery 70 .…”
Section: Resultsmentioning
confidence: 99%
“…Differently, Lee et al made use of a mandibular implant without the support of a bone autograft, proving an acceptable alternative in cases of unsuitable free flap surgery 70 . A total of 27 patients (81.9%) showed good aesthetical and occlusion outcomes and thus correct oral rehabilitation 68 70 77 78 88 94 96 97 113 128 . Complications were observed in 2 subjects (6%): one patient experienced bone resorption and infection, while the other had flap necrosis 77 113 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…VSP is increasingly applied especially in two or more segmented mandible reconstruction cases to facilitate osteotomies and thus enhance accuracy. Several authors describe advantages of this method regarding reduced operating time and increased precision of reconstruction with comparable complication rates [2,4,[9][10][11][12][13][14][15][16][17]. Critical points are the additional costs and time for preoperative planning and that the strategy is superfluous in the case of positive margins or other reasons for intraoperative treatment concept modification [18][19][20].…”
Section: Discussionmentioning
confidence: 99%
“…Unfortunately, however, positioning a fibula segment in the mandible is more difficult during an actual reconstruction surgery than it is in the surgical simulation. Methods for placing the fibula bone segments into mandibular reconstruction sites have been reported previously [ 6 , 7 ]. Fibula segments can be fixed with plates of various sizes and materials, including metal reconstructive plates, mini plates, or resorbable plates.…”
Section: Introductionmentioning
confidence: 99%