2015
DOI: 10.1049/iet-gtd.2015.0407
|View full text |Cite
|
Sign up to set email alerts
|

Proposition of an interharmonic‐based methodology for high‐impedance fault detection in distribution systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0
31

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(54 citation statements)
references
References 10 publications
0
23
0
31
Order By: Relevance
“…But none of these researches have worked on EMI owing to the HIFs. Moreover, HIFs occur on various materials such as live tree, asphalt or concrete, and each results in different features such as fault current amplitude [10,11]. So, it is not applicable to use same detection techniques for all types of HIF.…”
Section: Introductionmentioning
confidence: 99%
“…But none of these researches have worked on EMI owing to the HIFs. Moreover, HIFs occur on various materials such as live tree, asphalt or concrete, and each results in different features such as fault current amplitude [10,11]. So, it is not applicable to use same detection techniques for all types of HIF.…”
Section: Introductionmentioning
confidence: 99%
“…Many fault features have been extracted and the highly recognized ones are: radiation behavior [1][2][3] and harmonic distortions in voltage and current [4][5][6][7][8][9]. Plenty of detection algorithms have been proposed and analyzed, including electromagnetic radiation based algorithms [3], harmonic based algorithms [4][5][6][7][8][9][10][11][12][13][14], wavelet based algorithms [15][16][17], instantaneous power based algorithms [18], and some intelligent detection algorithms [19,20]. Due to the obvious 3 rd harmonic characteristic of HIFs, the harmonic based algorithms are the most commonly adopted in industrial application.…”
Section: Introductionmentioning
confidence: 99%
“…Experimentos realizados por [10] evidenciaram que a corrente produzida por uma FAI não é simétrica possuindo o semiciclo positivo maior em amplitude se comparado com o semiciclo negativo. [40], em uma superfície de areia, dentro das faixas especificadas pela metodologia analisada. A Figura 4.23 apresenta as magnitudes, em percentual da fundamental, dos conteúdos inter-harmônicos de 4a ordem da forma de onda simulada, para a FAI produzida em [40], em uma superfície de areia, dentro das faixas especificadas pela metodologia analisada.…”
Section: Assimetriaunclassified
“…Na Figura 4.30 é possível verificar que as magnitudes dos conteúdos interharmônicos da forma de onda simulada, para a FAI produzida em [40], em uma superfície de brita, dentro das faixas especificadas pela metodologia analisada, se encontram entre 7 e 0,5 por cento da magnitude da corrente na frequência fundamental. [40], em uma superfície de brita, dentro das faixas especificadas pela metodologia analisada. [40], em uma superfície de capim, dentro das faixas especificadas pela metodologia analisada, se encontram entre 6 e 0,3 por cento da magnitude da corrente na frequência fundamental.…”
Section: > Espectro De Frequências Da Fai Aplicada Na Superfície Britaunclassified
See 1 more Smart Citation