2017
DOI: 10.1016/j.ijrobp.2017.04.027
|View full text |Cite
|
Sign up to set email alerts
|

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
153
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 145 publications
(170 citation statements)
references
References 18 publications
2
153
0
Order By: Relevance
“…Their horizontal error bar is set to 0.5 mm (commissioning tolerance), while the vertical error represents the predicted statistical uncertainty ∆ s ×Ṅ d,all assuming N p = 10 8 protons per spot cluster. 20 30 40 Modeled γ-ray count rateṄ d,all as a function of proton range Rw, cf. eqs.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Their horizontal error bar is set to 0.5 mm (commissioning tolerance), while the vertical error represents the predicted statistical uncertainty ∆ s ×Ṅ d,all assuming N p = 10 8 protons per spot cluster. 20 30 40 Modeled γ-ray count rateṄ d,all as a function of proton range Rw, cf. eqs.…”
Section: Resultsmentioning
confidence: 99%
“…It is common practice in Pencil Beam Scanning (PBS) to aggregate data from neighboring spots [20], [21], [42] in order to achieve around N p ∼ 10 8 protons per cluster. Since the lateral spread of the pencil beam close to the proton range is often larger than the lateral separation between pencil beams, an improvement in statistical precision can be achieved without significant loss in lateral resolution.…”
Section: Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are currently two PGI systems based on collimated systems that have reached the clinical prototype for proton range verification. The first application in men was the knife‐edge slit camera from IBA * 18,19 . This device retrieves the relative changes in the total prompt gamma emission profile along the Bragg peak.…”
Section: Introductionmentioning
confidence: 99%
“…The first application in men was the knifeedge slit camera from IBA*. 18,19 This device retrieves the relative changes in the total prompt gamma emission profile along the Bragg peak. The second prototype is a promptgamma spectroscope developed at the MGH † that measures the absolute deviations with respect to the plan and it is foreseen for application in a upcoming clinical study.…”
Section: Introductionmentioning
confidence: 99%