Electrodermal Activity 2011
DOI: 10.1007/978-1-4614-1126-0_1
|View full text |Cite
|
Sign up to set email alerts
|

Principles of Electrodermal Phenomena

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
49
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(52 citation statements)
references
References 114 publications
1
49
0
1
Order By: Relevance
“…Following previous studies (e.g., Armel and Ramachandran, 2003) we used SCR to assess affective reactivity (see Figner and Murphy, 2010; Boucsein, 2011). SCR is a standard physiological measure and the best predictor of psychological arousal, and the fact that participants cannot control their SCR voluntarily makes it a reliable measure.…”
Section: Methodsmentioning
confidence: 99%
“…Following previous studies (e.g., Armel and Ramachandran, 2003) we used SCR to assess affective reactivity (see Figner and Murphy, 2010; Boucsein, 2011). SCR is a standard physiological measure and the best predictor of psychological arousal, and the fact that participants cannot control their SCR voluntarily makes it a reliable measure.…”
Section: Methodsmentioning
confidence: 99%
“…High physiological sensitivity would be reflected in higher average amplitude. The method applied for calculating the response average (stimulus average) was based on a well-documented methodology applied in the field of EDA (Boucsein, 2012). We were specifically interested in skin conductance response (SCR), the phasic change in EDA -a fast change in the amplitude of the signal relative to baseline.…”
Section: Definition Of Habituation and Sensitivity At The Physiologicmentioning
confidence: 99%
“…Minimal response criterion was set to 0.02 μ S, and responses that did not pass this criterion were scored as 0. SCR scores were then ztransformed to normalize the distributions (Boucsein, 2012). Clean SCRs were then used for subsequent statistical comparisons.…”
Section: Discussionmentioning
confidence: 99%
“…Ag-AgCl electrodes were attached to the middle and index fingers from the hand not receiving shocks. A conducting gel was used to improve signal quality, in accordance with standard recommendations (Boucsein, 2012). Electric shocks (aversive stimuli) were delivered using a STM200 module (BIOPAC Systems Inc., Goleta, CA, USA).…”
Section: Data Acquisitionmentioning
confidence: 99%