Preparation of standard vapor-gas mixtures for gas chromatography: continuous gas extraction

Abstract: Science Program at USC, and tothe Swedish Environmental Protection Board for their encouragement and financial (30) Yalkowski, S. H.; Valvanl, S. C.; Mackay, D. Residue Rev. 1083, 85, 43-55. (31) Aibro, P. W.; Corbett, J. T.; Schroeder, J. L. J . Chromatogr. The possibilities of using gas extractlon under dynamic conditlons in preparing gas mlxtures of known concentratlons for equipment testing and the development of analytical technlques are discussed. Conditions are specified for the preparation of mixtures … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2004
2004
2011
2011

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Hence, several authors, particularly from Russia, prefer to use the term "continuous gas extraction". 21,22 A scheme of the dilutor technique used in the present work is shown in Figure 1. This kind of equipment was already described previously.…”
Section: Methodsmentioning
confidence: 99%
“…Hence, several authors, particularly from Russia, prefer to use the term "continuous gas extraction". 21,22 A scheme of the dilutor technique used in the present work is shown in Figure 1. This kind of equipment was already described previously.…”
Section: Methodsmentioning
confidence: 99%
“…Standard gases with concentrations in air of styrene and p-xylene beginning at 1.18 ppm (5.6 mg/m 3 ), and of toluene and benzene of 2.18 ppm (7.8 mg/m 3 ), were prepared using a head space vapor-gas source (HSVS) [5]. Polydimethylsiloxane in the shape of a tube 30 mm long and with inner and outer diameters of 0.63 mm and 1.18 mm, respectively, was used as the first membrane of the inlet system.…”
Section: Devices and Standards Usedmentioning
confidence: 99%
“…When analyzing air mixtures during our experimental check of the inlet system, a (HSVS) [5] was used that ensured constant concentrations (the error was no greater than 7%) of the target components: 2.2 ppm for toluene, 1.8 ppm for benzene, and 1.2 ppm for styrene and p-xylene at an ambient temperature of 20°ë in a sample flow of up to 300 mL/min.…”
Section: Air Samplesmentioning
confidence: 99%
“…Gas standards of toluene, benzene, styrene, and p-xylene of 1.18 ppm-2.18 ppm (or 5.6 mg/m 3 -7.8 mg/m 3 ) concentrations in 95% nitrogen and 5% oxygen mixture were prepared using a head 1,2,3) through the multimembrane inlet system into a mass spectrometer and relative enrichment of the sample with compounds with the different permeabilities ( c ) in non-steady-state sudden sampling introduction mode depend on the extension of the time interval between the moment of sample supply to the inlet system and the time of measurement t I , t II , or t III , where t c ss is the time required to achieve steady state flow of Compound c through the entire membrane inlet, c is the response time of Compound c for a one membrane interface. space vapor-gas source (HSVS) [10], allowing the preparation of gas mixtures with vapor concentrations from 0.01 to 1000 mg/m 3 for volatile organic compounds. The uncertainty in the preparation of the gas mixtures with the HSVS is 2-7% at constant temperature.…”
Section: Standardsmentioning
confidence: 99%