1996
DOI: 10.1002/(sici)1099-0518(19960115)34:1<141::aid-pola15>3.0.co;2-l
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Preparation and characterization of a homobifunctional silicone rubber membrane grafted with acrylic acid via plasma-induced graft copolymerization

Abstract: Polyacrylic acid (PAA) was grafted onto the surface of silicone rubber membrane (SR) by plasma‐induced graft copolymerization (PIP). Ar‐plasma was used to activate the surface of SR. Also, a determination was made of the influences of plasma treatment power, pressure, time, grafted copolymerization reaction time, and monomer concentration on polymerization yield. The surface properties of SR were measured by ATR‐FTIR, ESCA, and SIMS. In those analyses, the elemental composition and different carbon bindings on… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
42
10
8
2

Citation Types

1
46
1
1

Year Published

1996
1996
2024
2024

Publication Types

Select...
51
4
1
1

Relationship

3
54

Authors

Journals

citations

Cited by 57 publications

(49 citation statements)
references

References 3 publications

1
46
1
1
Order By: Relevance
How this paper cites the one you are viewing
“…In contrast to other studies on graft polymerization using a direct plasma technique, our work showed peroxide groups could be efficient initiators of graft polymerization on the plasma‐treated surfaces 7. Several investigations have revealed that application of DPPH is highly effective for determining the amount of peroxide groups on the activated polymer surface 7–9. The number of peroxide groups increases with the increase in plasma treatment time, reaching a plateau at treatment times of 20, 40, and 50 s under 30, 20, and 10 W of power, respectively, and decreases thereafter (Figure 1).…”
Section: Results
contrasting
confidence: 89%
“…Clearly, longer Ar plasma exposure does not guarantee high peroxide formation. It should be noted that low peroxide concentrations at long plasma exposures were not due to direct decomposition of the formed peroxide by the plasma because the plasma exposure was carried out in an atmosphere containing only the Ar gas, which should result in no peroxide formation 7–9. Thus, the peroxides must have been produced during the exposure of the samples to oxygen atmosphere after the plasma treatment, as proposed by Suzuki and colleagues 7…”
Section: Results
mentioning
confidence: 97%
See 1 more Smart Citation
How this paper cites the one you are viewing
“…In contrast to other studies on graft polymerization using a direct plasma technique, our work showed peroxide groups could be efficient initiators of graft polymerization on the plasma‐treated surfaces 7. Several investigations have revealed that application of DPPH is highly effective for determining the amount of peroxide groups on the activated polymer surface 7–9. The number of peroxide groups increases with the increase in plasma treatment time, reaching a plateau at treatment times of 20, 40, and 50 s under 30, 20, and 10 W of power, respectively, and decreases thereafter (Figure 1).…”
Section: Results
contrasting
confidence: 89%
“…Clearly, longer Ar plasma exposure does not guarantee high peroxide formation. It should be noted that low peroxide concentrations at long plasma exposures were not due to direct decomposition of the formed peroxide by the plasma because the plasma exposure was carried out in an atmosphere containing only the Ar gas, which should result in no peroxide formation 7–9. Thus, the peroxides must have been produced during the exposure of the samples to oxygen atmosphere after the plasma treatment, as proposed by Suzuki and colleagues 7…”
Section: Results
mentioning
confidence: 97%
How this paper cites the one you are viewing
“…The analysis of experimental data indicates that the grafted amount has decreased after passing a maximum at 35 s (60 W). The previous studies have shown that the peroxide groups act as initiators in plasma‐induced graft copolymerization 12, 17, 28, 34. According to our results, the changes of the grafted amount as a function of the pretreatment time directly depend on those of the peroxides concentration (Figs.…”
Section: Results
supporting
confidence: 76%
How this paper cites the one you are viewing
“…According to our results, as shown in Fig. 25,26 The reasons for plasma pretreatment of the films before grafting are: In other words, this occurrence could be accounted by the produced peroxides that were partially converted into inactive species and not as free radicals into after prolonged plasma pretreatment times.…”
Section: Results
mentioning
confidence: 64%