2023
|
Sign up to set email alerts
Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Patellar Tendon: A Cadaveric Study
Abstract: For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of … Show more
Search citation statements
Order By: Relevance
Paper Sections
Select...
4
3
2
1
Citation Types
2
12
0
0
Year Published
Range
2024
20242026
2026Publication Types
Select...
8
Relationship
2
6
Authors
Journals
Cited by 8 publications
(14 citation statements)
References 51 publications
2
12
0
0
Order By: Relevance
The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
Healthcare
Self Cite
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s). Again, these results are also similar to those in previous studies conducted on the knee [13] and elbow [24] regions. Differences in outcomes might occur since ultrasound guidance offers visual cues regarding needle placement, allowing therapists to refine and enhance their technique until reaching the exact target point, thus potentially prolonging the necessary time of the approach.…”
Section: Discussion
supporting
confidence: 91%
“…In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm). Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s).…”
Section: Discussion
supporting
confidence: 86%
“…Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm).…”
Section: Discussion
mentioning
confidence: 80%
“…Previous studies using ultrasound-guidance approaches had attained accuracies ranging from 1.5 to 3.27 mm with different phantoms [17,22,23]. Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study.…”
Section: Discussion
mentioning
confidence: 90%
The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
Healthcare
Self Cite
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s). Again, these results are also similar to those in previous studies conducted on the knee [13] and elbow [24] regions. Differences in outcomes might occur since ultrasound guidance offers visual cues regarding needle placement, allowing therapists to refine and enhance their technique until reaching the exact target point, thus potentially prolonging the necessary time of the approach.…”
Section: Discussion
supporting
confidence: 91%
“…In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm). Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s).…”
Section: Discussion
supporting
confidence: 86%
“…Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm).…”
Section: Discussion
mentioning
confidence: 80%
“…Previous studies using ultrasound-guidance approaches had attained accuracies ranging from 1.5 to 3.27 mm with different phantoms [17,22,23]. Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study.…”
Section: Discussion
mentioning
confidence: 90%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…PE administration under US guidance seems to be a valid option to raise its effectiveness and safety. US-guided invasive procedures are usually more precise, as also confirmed by cadaver studies [ 4 , 62 , 73 ]. US provides real-time visualization, allowing for precise needle placement within pathological tissue, which is crucial for delivering the galvanic current effectively and minimizing harm to surrounding healthy structures.…”
Section: Discussion
mentioning
confidence: 91%
The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
Healthcare
Self Cite
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s). Again, these results are also similar to those in previous studies conducted on the knee [13] and elbow [24] regions. Differences in outcomes might occur since ultrasound guidance offers visual cues regarding needle placement, allowing therapists to refine and enhance their technique until reaching the exact target point, thus potentially prolonging the necessary time of the approach.…”
Section: Discussion
supporting
confidence: 91%
“…In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm). Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s).…”
Section: Discussion
supporting
confidence: 86%
“…Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm).…”
Section: Discussion
mentioning
confidence: 80%
“…Previous studies using ultrasound-guidance approaches had attained accuracies ranging from 1.5 to 3.27 mm with different phantoms [17,22,23]. Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study.…”
Section: Discussion
mentioning
confidence: 90%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…PE administration under US guidance seems to be a valid option to raise its effectiveness and safety. US-guided invasive procedures are usually more precise, as also confirmed by cadaver studies [ 4 , 62 , 73 ]. US provides real-time visualization, allowing for precise needle placement within pathological tissue, which is crucial for delivering the galvanic current effectively and minimizing harm to surrounding healthy structures.…”
Section: Discussion
mentioning
confidence: 91%
The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
Healthcare
Self Cite
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s). Again, these results are also similar to those in previous studies conducted on the knee [13] and elbow [24] regions. Differences in outcomes might occur since ultrasound guidance offers visual cues regarding needle placement, allowing therapists to refine and enhance their technique until reaching the exact target point, thus potentially prolonging the necessary time of the approach.…”
Section: Discussion
supporting
confidence: 91%
“…In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm). Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s).…”
Section: Discussion
supporting
confidence: 86%
“…Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm).…”
Section: Discussion
mentioning
confidence: 80%
“…Previous studies using ultrasound-guidance approaches had attained accuracies ranging from 1.5 to 3.27 mm with different phantoms [17,22,23]. Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study.…”
Section: Discussion
mentioning
confidence: 90%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…PE administration under US guidance seems to be a valid option to raise its effectiveness and safety. US-guided invasive procedures are usually more precise, as also confirmed by cadaver studies [ 4 , 62 , 73 ]. US provides real-time visualization, allowing for precise needle placement within pathological tissue, which is crucial for delivering the galvanic current effectively and minimizing harm to surrounding healthy structures.…”
Section: Discussion
mentioning
confidence: 91%