2023
DOI: 10.3390/life13102060
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Patellar Tendon: A Cadaveric Study

Abstract: For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of … Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
3
2
1

Citation Types

2
12
0
0

Year Published

Range
2024
2024
2026
2026

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations

Cited by 8 publications

(14 citation statements)
references

References 51 publications

2
12
0
0
Order By: Relevance
How this paper cites the one you are viewing
“…Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s). Again, these results are also similar to those in previous studies conducted on the knee [13] and elbow [24] regions. Differences in outcomes might occur since ultrasound guidance offers visual cues regarding needle placement, allowing therapists to refine and enhance their technique until reaching the exact target point, thus potentially prolonging the necessary time of the approach.…”
Section: Discussion
supporting
confidence: 91%
“…In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm). Nevertheless, to achieve this accuracy, the ultrasound-guided approach required significantly more time (mean: 53.8 ± 18.9 s) than the landmark-guided approach (mean: 19.1 ± 6.5 s).…”
Section: Discussion
supporting
confidence: 86%
“…Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study. Arias-Buría et al [13] also found greater contact of the needle (mean: 15.5 ± 6.65 mm) on the targeted interphase than with the landmark-guided approach (mean: 0.25 ± 0.6 mm).…”
Section: Discussion
mentioning
confidence: 80%
“…Previous studies using ultrasound-guidance approaches had attained accuracies ranging from 1.5 to 3.27 mm with different phantoms [17,22,23]. Thus, previous studies performed with a similar methodology but in other body areas such the knee [13] or the elbow [24] also yielded a higher accuracy with ultrasound-guided approaches. In fact, Arias-Buría et al [13] also evaluated the accuracy of inserting a needle into the interface between the patellar tendon and Hoffa's fat pad and obtained similar results as in the current study.…”
Section: Discussion
mentioning
confidence: 90%
See 3 more Smart Citations