2021
DOI: 10.1017/s1047951121004133
|View full text |Cite
|
Sign up to set email alerts
|

Pre-procedural CT imaging aids neonatal PDA stenting for ductal-dependent pulmonary blood flow with reduction in overall procedural morbidity

Abstract: Patent ductus arteriosus stenting for ductal-dependent pulmonary blood flow is a technically challenging neonatal procedure to maintain a stable pulmonary circulation. Pre-procedural computed tomography imaging aids in outlining ductal origin, insertion, size, course and curvature. Computed tomography imaging may add value to procedural outcomes and reduce overall procedural morbidity in neonatal patent ductus arteriosus stenting. We conducted a single centre retrospective chart review of neonates with ductal-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 16 publications
(18 reference statements)
0
4
0
Order By: Relevance
“…In our center, CA or FA/FV approaches have similar high procedural success rates due to careful preprocedural echocardiography assessment to determine what access should be taken. If echocardiography visualization is not good enough and we doubt the PDA anatomy, a computed tomography scan would add value in outlining ductal origin, insertion, size, course and curvature [ 9 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In our center, CA or FA/FV approaches have similar high procedural success rates due to careful preprocedural echocardiography assessment to determine what access should be taken. If echocardiography visualization is not good enough and we doubt the PDA anatomy, a computed tomography scan would add value in outlining ductal origin, insertion, size, course and curvature [ 9 ].…”
Section: Discussionmentioning
confidence: 99%
“…The relatively shorter fluoroscopy time and procedural duration in the CA approach also proved that the CA approach is effective and efficient when PDA anatomy is favourable. [ 1 , 8 , 9 ]…”
Section: Discussionmentioning
confidence: 99%
“…A biplane overlay example (Siemens bi-plane system (Siemens Healthineers, Munich, Germany) is depicted in Figure 19 [13]. Overlay fusion has demonstrated a reduction in overall radiation burden [8,9].…”
Section: Cross-sectional Overlay Fusion In the Catheterization Labmentioning
confidence: 99%
“…Figure 9. Additional example of pre-procedural CT imaging (A) aiding with access site selection for successful PDA stenting (B,C) via the left axillary artery (LAA) to the left subclavian artery (LSCA).Revised from ref[9].…”
mentioning