2018
DOI: 10.2116/analsci.34.57
|View full text |Cite
|
Sign up to set email alerts
|

Practical High-Performance Lateral Flow Assay Based on Autonomous Microfluidic Replacement on a Film

Abstract: Although paper-based microfluidic devices are an ideal platform for point-of-care (POC) diagnostics, it is difficult to achieve microfluidic control required for sensitive analyses such as ELISA on a paper substrate. Here, we present a novel lateral-flow test chip that can perform operations similar to a pump, such as flowing, stopping, and replacing a solution, just by adding the solution onto an inlet port. The chip was fabricated by laminating paper, film, and adhesive tape. For sensitive and accurate detec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…They tested the performance of their system against a conventional C-reactive protein LFA and reported 1000-fold sensitivity improvement in their system over the LFA. 81 Limitations. The transport/signal category contains complementary approaches to the reduction of optical noise in LFAs.…”
Section: Transport/signalmentioning
confidence: 99%
“…They tested the performance of their system against a conventional C-reactive protein LFA and reported 1000-fold sensitivity improvement in their system over the LFA. 81 Limitations. The transport/signal category contains complementary approaches to the reduction of optical noise in LFAs.…”
Section: Transport/signalmentioning
confidence: 99%
“…Comparing the LOD and detection range, the developed weakly ionized AA-AuNP LFIAs are superior to the reported fluorescent LFIAs and CL LFIAs (Fig. 4, G to I, and table S1) (9,22,25,(53)(54)(55)(56)(57). When taking the LOD value as an index, the straightforward colorimetric AA-AuNP LFIAs are comparable to the complicated SERS LFIAs and nanozyme LFIAs (table S1) (39,(58)(59)(60)(61).…”
Section: Resultsmentioning
confidence: 83%
“…[8,9] Immunoaffinity chromatography, a typical simple diagnostic tool, can detect antigens in a short time (<10 min), but its sensitivity is low (approximately 10 × 10 11 /mL), and quantitative measurement is difficult. [10,11] When more sensitive and quantitative detection is required, enzyme-linked immunosorbent assay (ELISA) is often employed.…”
Section: Introductionmentioning
confidence: 99%