2018 IEEE 8th Power India International Conference (PIICON) 2018
DOI: 10.1109/poweri.2018.8704455
|View full text |Cite
|
Sign up to set email alerts
|

Power Quality Improvement of Single Phase Grid Connected Hybrid Solar PV and Wind System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 11 publications
0
6
0
Order By: Relevance
“…Therefore, studies have suggested different technical solutions to mitigate these power quality issues, enhancing the DN HC. The impacts of DG's excessive penetration on aspects related to power quality are proposed in [51,57,59,109,[121][122][123][124][125][126][127].…”
Section: B Power Quality Compensationmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, studies have suggested different technical solutions to mitigate these power quality issues, enhancing the DN HC. The impacts of DG's excessive penetration on aspects related to power quality are proposed in [51,57,59,109,[121][122][123][124][125][126][127].…”
Section: B Power Quality Compensationmentioning
confidence: 99%
“…Therefore, an innovative dynamic mitigating strategy relying on community energy storage is presented in [124] to tackle this issue. Moreover, for power quality improvement in a single phase DN integrated into PV and wind energy generation system, an amplitude adaptive notch filter (AANF)-based control method is presented in [126]. The system's performance is evaluated on a designed prototype in the laboratory.…”
Section: B Power Quality Compensationmentioning
confidence: 99%
“…3a. The feed-forward term represents the amplitude of the grid current for lossless ideal system and at no-load at the common point of interconnection (CPI) [9,10].…”
Section: Grid-interfaced Voltage Source Convertermentioning
confidence: 99%
“…A 40 kVA Static Compensator dynamically adjusting the rapid voltage changes by reactive power injection/absorption is employed in [47] to reduce the fluctuations from 8% to less than 5% thus improving PQ. Similarly, the Power Quality of a single-phase grid is improved in [129] through a control algorithm based on Amplitude Adaptive Notch Filter. The proposed strategy employs voltage source converters to improve the Power Quality, coupling inductor to decrease harmonics in grid current and RC filter for reducing higher-order harmonics.…”
Section: Power Quality Compensation (Harmonics Unbalance Flicker)mentioning
confidence: 99%