2020
DOI: 10.5013/ijssst.a.20.01.37
|View full text |Cite
|
Sign up to set email alerts
|

Power Management Strategy for Solar Photovoltaic Systems with Battery Protection Scheme in DC Microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…The algorithm employed in maximum power point tracking (MPPT) is 'ıncremental conductance + ıntegral regulator' [16]. The components contained in the detailed model [17], [18] are: a. PV Array: Maximum power delivered by PV array is 100 kW at 1000 W/m 2 solar irradiance. b. DC-DC boost converter: At maximum power, PV output voltage is 273 V DC which is increased to 500 V DC by DC-DC boost converter of 5-kHz.…”
Section: Detailed Description Of 100 Kw Utility Grid Connected Pv Arraymentioning
confidence: 99%
“…The algorithm employed in maximum power point tracking (MPPT) is 'ıncremental conductance + ıntegral regulator' [16]. The components contained in the detailed model [17], [18] are: a. PV Array: Maximum power delivered by PV array is 100 kW at 1000 W/m 2 solar irradiance. b. DC-DC boost converter: At maximum power, PV output voltage is 273 V DC which is increased to 500 V DC by DC-DC boost converter of 5-kHz.…”
Section: Detailed Description Of 100 Kw Utility Grid Connected Pv Arraymentioning
confidence: 99%
“…The MGs possess the surplus amount of power to be supplied for the loads for better operations 19 . With the aid of utilizing the RER capacity completely and improving the performance of the MG in supplying the power, the MGs are powered with the capability of operating in two modes such as the off‐grid mode or the islanded (IS) mode and the on‐grid mode or the grid‐connected (GC) mode 20‐22 . The IS mode provides a facility for the MG to work on with its frequency and voltage values, and for the GC mode, the utility grid's line voltage and line frequency are followed by the MG 23 .…”
Section: Introductionmentioning
confidence: 99%
“…19 With the aid of utilizing the RER capacity completely and improving the performance of the MG in supplying the power, the MGs are powered with the capability of operating in two modes such as the off-grid mode or the islanded (IS) mode and the on-grid mode or the grid-connected (GC) mode. [20][21][22] The IS mode provides a facility for the MG to work on with its frequency and voltage values, and for the GC mode, the utility grid's line voltage and line frequency are followed by the MG. 23 The MGs are also subjected to a dynamic mode of operation called the transition periods, during which the elements of MG face abnormal fluctuations between the voltage and frequency, leading to stability and power quality (PQ) problems. 24,25 These fluctuations are effectively reduced with the help of an efficient storage system that can store the energy and prevent the loss of energy while it is supplied for the loads by the MGs.…”
Section: Introductionmentioning
confidence: 99%
“…In previous works, controllers for integrating the batteries with PV arrays have used multiple H bridges [13]. The power generated from the PV array is converted to AC, and then if excess power is generated, AC to DC converters is used to charge the batteries [14]. The AC-DC converters need complex gating signals and introduce harmonics in the output power, thus reducing the power quality.…”
Section: Introductionmentioning
confidence: 99%