Power management in PV‐battery‐hydro based standalone microgrid

Abstract: This work deals with the frequency regulation, voltage regulation, power management and load levelling of solar photovoltaic (PV)-battery-hydro based microgrid (MG). In this MG, the battery capacity is reduced as compared to a system, where the battery is directly connected to the DC bus of the voltage source converter (VSC). A bidirectional DC-DC converter connects the battery to the DC bus and it controls the charging and discharging current of the battery. It also regulates the DC bus voltage of VSC, freque… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
38
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 83 publications
(38 citation statements)
references
References 29 publications
(41 reference statements)
0
38
0
Order By: Relevance
“…To evaluate future research tendencies, the articles which were published between 2010 and 2019 were analyzed respecting the scientific literature gaps which they propose. Of the 3260 articles on solar PV energy management that were published between 2010 and 2019, 235 were not accessible, 955 did not apply to research and 1917 did not include proposals for further research ( Figure 3 ) [ 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 …”
Section: Resultsmentioning
confidence: 99%
“…To evaluate future research tendencies, the articles which were published between 2010 and 2019 were analyzed respecting the scientific literature gaps which they propose. Of the 3260 articles on solar PV energy management that were published between 2010 and 2019, 235 were not accessible, 955 did not apply to research and 1917 did not include proposals for further research ( Figure 3 ) [ 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 …”
Section: Resultsmentioning
confidence: 99%
“…Actually, (1) is not able to answer the question that whether shutting down a gas turbine is cheaper or changing the (30). In (27), the first and second terms are the start-up and shutdown costs, respectively. The third term demonstrates the sum of fuel cost of generators.…”
Section: Modellingmentioning
confidence: 99%
“…However, as the commutation failure is the most common fault in the thyristorbased converters, this type of converter is not suitable for the purpose of this paper and is not surveyed here [26]. Depending on the application, different converters and various switching algorithms have been proposed to connect power supplies and loads, which would impose multiple restrictions such as active power exchange restriction, reactive power control, total harmonic distortion (THD) limitation etc [20,27,28]. Among all mentioned restrictions, THD would have the greatest impact on the final results since IEEE 519-2014 coerces that the amount of voltage THD in a distribution network must be lower than 5%, and hence it might impose penalties which affect the total operation cost of an MG. Harmonic injection is one of the main concerns since these harmonics increase power losses and may cause stability problems in the grid [29,30].…”
Section: Introductionmentioning
confidence: 99%
“…In [7], the PM for a MG consisting of a photovoltaic (PV), a wind turbine (WT), a distributed generator, and a battery bank with linear and non-linear loads was achieved through the utilization of the adaptive neuro fuzzy inference system )ANFIS( with elephant herd optimization (EHO) algorithm. The authors in [8] introduced a PM system for PV-battery-hydro based MG capable of regulating the frequency and voltage of the MG and load leveling and organized the active power circulating during battery charging and discharging. Similarly, in [9], a PV/battery hybrid distributed power generation system was proposed with a power management strategy (PMS) of only one integrated three-port power converter.…”
Section: Introductionmentioning
confidence: 99%