2015
DOI: 10.1016/j.meddos.2014.11.004
|View full text |Cite
|
Sign up to set email alerts
|

Postoperative radiotherapy following mastectomy for patients with left-sided breast cancer: A comparative dosimetric study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
36
7
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(44 citation statements)
references
References 17 publications
0
36
7
1
Order By: Relevance
“…However, according to literature and our previous experience, tangential PMRT could introduce large dose heterogeneities in the PTV and can induce suboptimal cosmesis after treatment. In addition, tangential PMRT would introduce higher heart dose and slightly lower lung dose than bolus electron conformal therapy without mixing with IMRT, and would introduce higher lung, heart, and coronary artery doses than VMAT …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, according to literature and our previous experience, tangential PMRT could introduce large dose heterogeneities in the PTV and can induce suboptimal cosmesis after treatment. In addition, tangential PMRT would introduce higher heart dose and slightly lower lung dose than bolus electron conformal therapy without mixing with IMRT, and would introduce higher lung, heart, and coronary artery doses than VMAT …”
Section: Discussionmentioning
confidence: 99%
“…In addition, tangential PMRT would introduce higher heart dose and slightly lower lung dose than bolus electron conformal therapy without mixing with IMRT, 14 and would introduce higher lung, heart, and coronary artery doses than VMAT. 51 Potential future work for this study could be adding intensity modulated electron therapy (IMET) 16 for the chest wall into the study. This technique could potentially reduce dose spread and the magnitude of hot spots and reduce skin complications, which could remove the need for the VMAT component of our mixed beam.…”
Section: Discussionmentioning
confidence: 99%
“…However, this value did not yield good agreement between measurements and TPS calculations for both 6 and 18 MV photon beams; Trombetta et al20 assigned the density of the metallic port in the Eclipse TPS to be 5 g/cm 3 which is the highest available value in the system. Except for one abstract19 in which the details and accuracy of the model were not provided, none of the previous studies created and validated a model of the metallic port with generic dimensions and density that can be applied to different beam energies, neither did they investigate the impact of the metallic port on any advanced techniques like intensity‐modulated radiotherapy (IMRT) or volumetric‐modulated arc therapy (VMAT), while these techniques have been used to treat postmastectomy patients 26…”
Section: Introductionmentioning
confidence: 99%
“…for patients with advanced disease, supraclavicular and axillary nodes are treated with additional photon fields. [2] In the past decades, many advanced technologies had been used for PMRT and shown promising results, such as intensity-modulated radiation therapy (IMRT), [3] standard volumetric modulated arc therapy (STD-VMAT), [4] non-coplanar VMAT (NC-VMAT), [5] multiple arc VMAT (MA-VMAT), [5] Tomotherapy (TOMO), [4] bolus electron conformal therapy (BECT), [6] BECT mixed with IMRT and VMAT (MIXED), [7] and proton therapy , [8] each with different degrees of sophistication and cost. Target coverage provided by most of these technologies is comparable, while the dose to surrounding normal tissues varies greatly.…”
Section: Introductionmentioning
confidence: 99%