2018
DOI: 10.1088/1757-899x/342/1/012084
|View full text |Cite
|
Sign up to set email alerts
|

Performance of unified power quality conditioner (UPQC) based on fuzzy controller for attenuating of voltage and current harmonics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…However, the proposed UPQC is based on a simpler fuzzy control. Table 6 gives a comparative study between the literature's P-Q UPQC [19], the literature's fuzzy controlled UPQC [20,21], and the proposed fuzzy UPQC in this work.…”
Section: Compared To the Conventional Upqc Control Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the proposed UPQC is based on a simpler fuzzy control. Table 6 gives a comparative study between the literature's P-Q UPQC [19], the literature's fuzzy controlled UPQC [20,21], and the proposed fuzzy UPQC in this work.…”
Section: Compared To the Conventional Upqc Control Methodsmentioning
confidence: 99%
“…The proposed method is a simple approach for effective current harmonics compensation and voltage sags and swells compensation. In order to compare the proposed approach with the conventional P-Q method [19] and the literature's fuzzy controlled UPQC [20,21], each method is simulated on the system under study at the fifth hour and sixth hour.…”
Section: Compared To the Conventional Upqc Control Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The widespread use of power electronic-based equipment and inductive/capacitive loads have brought power quality problems in distribution systems. The most common power quality problems today are low PF and harmonic distortion [1,2]. The low PF and Harmonic currents in the distribution system can cause heating in the electrical equipment, vibration/noise in machines, and malfunction of the sensitive equipment [3].…”
Section: Introductionmentioning
confidence: 99%
“…Several control strategies have been developed for the determination of the reactive and harmonic load current components. Such strategies include the p-q theory and the SRF which have performed equally although their differences are evident when working under unbalanced and distorted AC voltages [9][10][11][12]. The self-tuning filters (STF) classical PQ theory served as the basis in this paper for the generation of the shunt HAPF control reference current under distorted voltage conditions.…”
Section: Introductionmentioning
confidence: 99%