2021
DOI: 10.11591/ijece.v11i1.pp84-93
|View full text |Cite
|
Sign up to set email alerts
|

Abstract: Harmonic Distortion in many of the industrial applications are occur primarily owing to the enormous utilization of loads with high non-linearity like power converters, speed varying drives and arc furnaces. The power semiconductor is used to achieve the variation in speed and conversion from one source to another. Mostly active filters and tuned filters are utilized to remove the harmonic included in the source current. The tuned passive filters and inductance inserted in the line reduces the harmonics but at… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…To compensate for HH currents and voltages in high-voltage mine networks with powerful nonlinear loads, various types of technical means can be used such as passive filters (PF), active filters (AF), and hybrid filters [12]- [22]. One of the most widespread, convenient and practically applicable technical means of compensation of HH components of currents and voltages in high-voltage mining networks are passive filters, which, despite the appearance of active filters, remain in demand [15]- [19].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…To compensate for HH currents and voltages in high-voltage mine networks with powerful nonlinear loads, various types of technical means can be used such as passive filters (PF), active filters (AF), and hybrid filters [12]- [22]. One of the most widespread, convenient and practically applicable technical means of compensation of HH components of currents and voltages in high-voltage mining networks are passive filters, which, despite the appearance of active filters, remain in demand [15]- [19].…”
Section: Methodsmentioning
confidence: 99%
“…Based on the foregoing, to compensate for HH currents and voltages, to ensure electromagnetic compatibility (EMC) in high-voltage mine networks with powerful non-linear consumers, it is advisable to use three-phase three-wire passive filters of various orders, mainly with parallel connection, tuned to one or more frequencies of higher harmonics. Also, the use of passive harmonic filters is based on the analysis of technical and economic indicators of the efficiency of compensation of HH currents and voltages in highvoltage mine networks in the presence of powerful nonlinear consumers [12]- [14].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Its power quality indicator values like THD, current, and voltage degree of corrections, voltage dips, and deviations, and current consumption are analyzed. Thentral et al [27] describe the hybrid active power filter using PQ-theory and space-vector pulse width modulation (SVPWM) method. The design uses a 7 th tuned harmonic passive filter connected series with an active filter to mitigate the THD.…”
Section: Review On Related Researchmentioning
confidence: 99%
“…The performance of SAPF depends on control strategies applied [17]. Control of DC capacitor voltage, generation of reference current and generation of gate pulse are the main concern while operating SAPF.…”
Section: Introductionmentioning
confidence: 99%