Percutaneous paravalvular leak closure after CoreValve transcatheter aortic valve implantation using an arterio-arterial loop

Abstract: Significant periprosthetic aortic regurgitation after transcatheter aortic valve implantation has become a major concern of this technique given its association with impaired survival. We report the successful closure of such defect using a vascular occlusion device with the creation of an arterio-arterial loop to gain enough support to advance the delivery sheath into de the left ventricle.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…In the majority of cases, SE valves require wire and catheter advancement through the valve struts and their manipulation can be challenging. Generally, it is difficult to advance delivery catheters, so the creation of an AA loop through the leak can be very helpful to cross through the SE struts and overcome the inner leak resistance ( 4 , 5 ). In the majority of patients, the use of an additional coronary wire (buddy wire) can help advance non-compliant balloon dilatation catheters with the aim of enlarging the hard-to-approach leakage.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the majority of cases, SE valves require wire and catheter advancement through the valve struts and their manipulation can be challenging. Generally, it is difficult to advance delivery catheters, so the creation of an AA loop through the leak can be very helpful to cross through the SE struts and overcome the inner leak resistance ( 4 , 5 ). In the majority of patients, the use of an additional coronary wire (buddy wire) can help advance non-compliant balloon dilatation catheters with the aim of enlarging the hard-to-approach leakage.…”
Section: Discussionmentioning
confidence: 99%
“…A high burden of calcium may persist in the TAVI device landing zone, limiting equipment accessibility and navigation between the prosthesis frame and native tissue (3). For anatomically hard-to-approach long calcified tracts, the use of a radial approach and the creation of an extra AA support loop can greatly facilitate the closure procedure (4)(5)(6).…”
mentioning
confidence: 99%
“…Mother and child catheter techniques or AV loops are of paramount importance in this setting as delivery catheters are generally difficult to advance. The creation of arterio-arterial or arterio-venous loops through the leak and antegrade progression of delivery catheters from the LV across the PVL may be very helpful to overcome the resistance in order to cross through the struts of the valve from a retrograde approach ( Figure 3 ) [ 21 ].…”
Section: Pvl Regurgitation After Tavi: Procedural Aspectsmentioning
confidence: 99%
“…However, in large and high volume leaks, for implanting the appropriate device, large sheaths may be needed. Particularly in self-expanding prostheses, valve struts and calcification of the annulus may complicate the advancement of delivery systems mainly when using large sheaths [23] .…”
Section: Central Leakmentioning
confidence: 99%