1983
Passive Eustachian Tube Opening Pressure: Its Measurement, Normal Values, and Clinical Implications
Search citation statements
Paper Sections
Select...
9
2
1
1
Citation Types
1
5
0
0
Year Published
1985
2026
Publication Types
Select...
13
Relationship
0
13
Authors
Journals
Cited by 13 publications
(6 citation statements)
References 15 publications
1
5
0
0
“…Previously reported data on healthy subjects showed a secondary opening pressure of 35 AE 10 cm of H 2 O. 14 We felt that our threshold of >50 cm of H 2 O roughly approximates the <55 cm of H 2 O value (m รพ 2s) for the 95% of healthy middle ear and Eustachian tubes.…”
Section: Methodssupporting
confidence: 66%
“…Previously reported data on healthy subjects showed a secondary opening pressure of 35 AE 10 cm of H 2 O. 14 We felt that our threshold of >50 cm of H 2 O roughly approximates the <55 cm of H 2 O value (m รพ 2s) for the 95% of healthy middle ear and Eustachian tubes.…”
Section: Methodssupporting
confidence: 66%
“…We assumed presence of obstruction and decided on dilatation based on a secondary opening pressure more than 50 cm of H 2 O. Previously reported data on healthy subjects showed a secondary opening pressure of 35 ยฑ 10 cm of H 2 O 14 . We felt that our threshold of >50 cm of H 2 O roughly approximates the <55 cm of H 2 O value (ฮผ + 2ฯ) for the 95% of healthy middle ear and Eustachian tubes.
- Valsalva CT
Section: Methodsmentioning
confidence: 91%
“…Tubomanometry (TMM) was first described by Estรจve in 2001, although a similar procedure was previously described by Moon et al . in 1983 . The patient is positioned seated with a tightโfitting pressure receiver in the external auditory canal, and a nasal applicator held tightly in place to allow the production of a defined pressure in the nasopharynx (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…4,5,7 Furthermore, alternative ETFTs, including sonotubometry, tubo-tympano-aerodynamic-graphy and tubomanometry, have been developed for the diagnosis of ETD. 3,6,[8][9][10] The critical disadvantage of the nine-step test is that can only be applied to a normal tympanic membrane, indicating an intact tympanic membrane with aerated middle ear cavity. For the reasons explained above, the nine-step test…”
Section: Introductionmentioning
confidence: 99%
“…Although sensitivity and specificity vary according to different cutโoff values and different definitions of Eustachian tube dysfunction (ETD), the reported sensitivity and specificity of the nineโstep test do not exceed 75% and 90%, respectively 4,5,7 . Furthermore, alternative ETFTs, including sonotubometry, tuboโtympanoโaerodynamicโgraphy and tubomanometry, have been developed for the diagnosis of ETD 3,6,8โ10 . The critical disadvantage of the nineโstep test is that can only be applied to a normal tympanic membrane, indicating an intact tympanic membrane with aerated middle ear cavity.…”
Section: Introductionmentioning
confidence: 99%
