2020
DOI: 10.1016/j.nima.2020.164372
|View full text |Cite
|
Sign up to set email alerts
|

Particle discrimination and fast neutron response for a NaIL:Tl and a NaI:Tl scintillator detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 22 publications
1
5
0
Order By: Relevance
“…After experimental tests, the measured energy spectra under three different shielding conditions are obtained, as shown in figure 3, in which the relationship between relative electronic energy and pulse integration has been obtained through energy calibration in advance. As can be seen from figure 3(a), a significant 6 Li(n,𝛼)T neutron capture peak appears due to a certain moderation of neutrons after the addition of HDPE shielding relative to the absence of shielding, within 2800-3900 keV energy window, similar to those reported in the literature [23]. After adding the lead brick shield, although the gamma event was largely reduced and the total event counts decreased significantly, the neutron capture peak was still visible.…”
Section: Spectrum and Pulse Waveformssupporting
confidence: 84%
See 1 more Smart Citation
“…After experimental tests, the measured energy spectra under three different shielding conditions are obtained, as shown in figure 3, in which the relationship between relative electronic energy and pulse integration has been obtained through energy calibration in advance. As can be seen from figure 3(a), a significant 6 Li(n,𝛼)T neutron capture peak appears due to a certain moderation of neutrons after the addition of HDPE shielding relative to the absence of shielding, within 2800-3900 keV energy window, similar to those reported in the literature [23]. After adding the lead brick shield, although the gamma event was largely reduced and the total event counts decreased significantly, the neutron capture peak was still visible.…”
Section: Spectrum and Pulse Waveformssupporting
confidence: 84%
“…where 𝜏 𝑓 is the fast component decay time constant, 𝜏 𝑠 is the slow component decay time constant, and 𝐴 and 𝐵 are the intensity coefficients of the two components, respectively. Studies have shown that the fast component usually dominates the pulses of NaIL scintillators [22,23], and the decay time constant of event pulses can be used to optimize frequency domain discrimination. According to Saleh's report [14], the optimal discriminating frequency can be obtained from eq.…”
Section: Length Of Pulse Transformationmentioning
confidence: 99%
“…Corresponding observations have been made by other authors (e.g. in [25]), but have not been interpreted correctly.…”
Section: Discussionmentioning
confidence: 61%
“…Therefore, it is important to discuss the contributions of other particles in the spectrum obtained from the NaI detector. There have been different studies on the efficiency of NaI (Tl) crystal to detect neutrons [20,27,28], and they concur that it is very low for lower energy neutrons (< 10 MeV). As pointed out by Arakelyan et al (2014) [20], the ratio of efficiencies of a NaI (Tl) detector to detect gamma and neutrons varies from 5:1 to 8:1 in the energy range 3 MeV-10 MeV.…”
Section: Jcap09(2021)045 4 Discussionmentioning
confidence: 97%