Partial discharges in a cavity embedded in oil-impregnated paper: effect of electrical and thermal aging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
20
1
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(26 citation statements)
references
References 20 publications
2
20
1
1
Order By: Relevance
“…In this paper, the concentration of dissolved gases is set to around 20,000 µL/L, which is an abnormal condition for the transformer as it close to the condition Level 2 in CIGRE 443 (17,193 µL/L). and IEC 60599 (20,750 µL/L), and also higher than that defined in IEEE C57.104 (condition Level 3, 16,030 µL/L).…”
Section: High Voltage Generation Unitmentioning
confidence: 99%
See 2 more Smart Citations
“…In this paper, the concentration of dissolved gases is set to around 20,000 µL/L, which is an abnormal condition for the transformer as it close to the condition Level 2 in CIGRE 443 (17,193 µL/L). and IEC 60599 (20,750 µL/L), and also higher than that defined in IEEE C57.104 (condition Level 3, 16,030 µL/L).…”
Section: High Voltage Generation Unitmentioning
confidence: 99%
“…• Cavity discharge (partial discharge in spherical cavities or gaps within a solid dielectric material) within insulation papers or pressboards [13][14][15][16][17][18][19][20][21], • Surface discharge in oil [13][14][15][16], • PD due to floating particles in oil [17,22], • Air bubble discharge in oil [14,17,22,23], • PD due to bad grounding (metal-to-metal discharge) [13], and • Oil wedge or metal protrusions caused PD in pure oil [13,22,[24][25][26][27].…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Assessment of insulation condition can be obtained by partial discharge (PD) monitoring [2]. For instance, some authors [3][4][5][6][7][8] have analysed the effect of oil and pressboard ageing (electrical and/or thermal) on the characteristic of PD from inception to flashover, surface discharge inception voltage (SDIV) variation, creepage discharge inception voltage (CDIV) or creepage discharge flashover voltage (CDFV) of oil/solid insulation specimens with different ageing degrees. Other authors have studied the effect of polarity on the accumulation of charges at the oil-solid interface [9], the accumulative effect of repeated lightning impulses and its damage mechanism [10], the electrical deterioration caused by PD under long-term AC voltage [11] or the performance of alternative liquids in comparison with mineral oil [12].…”
Section: Introductionmentioning
confidence: 99%
“…The thickness of the three-plate composite is 2.4 mm. The HV electrode is made from stainless steel with a well-rounded edge to avoid surface discharge from regions of elevated field strength [15].…”
Section: Introductionmentioning
confidence: 99%