2019
DOI: 10.1590/1982-0194201900014 View full text |Buy / Rent full text
|
|

Abstract: Objective: This study aims to compare water and power consumption in four cycle confi gurations (number of pulses in the conditioning phase, drying time, and vacuum depth set point) for steam sterilization. Methods: A descriptive study of four different cycle confi gurations: In confi guration A, conditioning phase vacuum pulses were set to a total of three, with a lower vacuum set point of 90 mbar and a higher pressure set point of 1500 mbar. The drying phase was set for 45 minutes with a vacuum level of 90 m… Show more

Help me understand this report

Search citation statements

Order By: Relevance
Select...
2
0
0
0
2

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

0
0
0
2
Order By: Relevance
“…Este recurso é indispensável para a realização das atividades em áreas específicas, como a esterilização, aquecimento ou resfriamento de equipamentos. (Durante, Oliveira Stiz, & Moreira, 2017) No contexto específico das CMEs, Laranjeira et al (2019) compararam o consumo de água e energia em quatro configurações de ciclo: número de pulsos na fase de condicionamento, tempo de secagem e valor de ajuste da profundidade do vácuo para esterilização a vapor. Nesse estudo, revelou-se que a fase de secagem de pacotes molhados após o ciclo de esterilização traz impactos ambientais, tendo em vista a grande utilização de água e energia durante esse ciclo.…”
Section: Discussionunclassified
See 1 more Smart Citation
Create an account to read the remaining citation statements from this report. You will also get access to:
  • Search over 1b+ citation statments to see what is being said about any topic in the research literature
  • Advanced Search to find publications that support or contrast your research
  • Citation reports and visualizations to easily see what publications are saying about each other
  • Browser extension to see Smart Citations wherever you read research
  • Dashboards to evaluate and keep track of groups of publications
  • Alerts to stay on top of citations as they happen
  • Automated reference checks to make sure you are citing reliable research in your manuscripts
  • 14 day free preview of our premium features.

Trusted by researchers and organizations around the world

Over 100,000 students researchers, and industry experts at use scite

See what students are saying

rupbmjkragerfmgwileyiopcupepmcmbcthiemesagefrontiersapsiucrarxivemeralduhksmucshluniversity-of-gavle
“…Este recurso é indispensável para a realização das atividades em áreas específicas, como a esterilização, aquecimento ou resfriamento de equipamentos. (Durante, Oliveira Stiz, & Moreira, 2017) No contexto específico das CMEs, Laranjeira et al (2019) compararam o consumo de água e energia em quatro configurações de ciclo: número de pulsos na fase de condicionamento, tempo de secagem e valor de ajuste da profundidade do vácuo para esterilização a vapor. Nesse estudo, revelou-se que a fase de secagem de pacotes molhados após o ciclo de esterilização traz impactos ambientais, tendo em vista a grande utilização de água e energia durante esse ciclo.…”
Section: Discussionunclassified
“…Nesse estudo, revelou-se que a fase de secagem de pacotes molhados após o ciclo de esterilização traz impactos ambientais, tendo em vista a grande utilização de água e energia durante esse ciclo. A secagem utilizada em pacotes molhados, deve ser a última opção a ser cogitada (Laranjeira et al, 2019).…”
Section: Discussionunclassified