2015
DOI: 10.1016/j.ejso.2015.08.112
|View full text |Cite
|
Sign up to set email alerts
|

P7. Intra-operative margin detection using Cerenkov Luminescence Imaging during radical prostatectomy – Initial results from the PRIME study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Still, precise patient dosage will be determined in our on-going clinical feasibility study. Prior studies with 18 F showed that the radiation dose to the surgeon due to the CLI procedure was 34 μSv per procedure and 2–20 μSv per scrub nurse [14, 16]. The use of 68 Ga-PSMA decreases the injected dose and thus improves the radiation safety for both the patient and personnel.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Still, precise patient dosage will be determined in our on-going clinical feasibility study. Prior studies with 18 F showed that the radiation dose to the surgeon due to the CLI procedure was 34 μSv per procedure and 2–20 μSv per scrub nurse [14, 16]. The use of 68 Ga-PSMA decreases the injected dose and thus improves the radiation safety for both the patient and personnel.…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, CLI has the advantage of using clinically approved imaging agents, which facilitates fast clinical translation of the technology. Academic researchers worldwide have already demonstrated the (pre-)clinical feasibility of CLI for intraoperative specimen analysis [8, 1416]. The first clinical trial for margin assessment with CLI, performed in breast cancer surgery with 18 Fluorine-Fluorodeoxyglucose ( 18 F-FDG), has shown promising initial results [16].…”
Section: Introductionmentioning
confidence: 99%
“…Patients undergoing a therapeutic radical prostatectomy receive a 370 MBq intravenous injection of 18 F-Choline, and the margins of the resected prostatectomy specimen are imaged using the investigational intraoperative CLI camera. The initial results show that intraoperative 18 F-Choline CLI is a feasible and low-risk procedure [ 57 ]. Elevated radiances were present in all three primary tumours (tumour-to-background ratio between 2.49 and 4.90), and CLI imaging did not add additional time to surgery.…”
Section: Applications Of CLI For Image-guided Surgery and Ongoing Climentioning
confidence: 99%