Overview of Photogrammetric Measurement Techniques in Minimally Invasive Surgery Using Endoscopes

Abstract: ABSTRACT:This contribution provides an overview of various photogrammetric measurement techniques in minimally invasive surgery and presents a self-developed prototypical trinocular endoscope for reliable surface measurements. Most of the presented techniques focus on applications regarding laparoscopy, which mean endoscopic operations in the abdominal or pelvic cavities. Since endoscopic operations are very demanding to the surgeon, various assistant systems have been developed. Imaging systems may use photog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…To analyze the frequencies and determine the distance to the surface, a Fourier transform is used [88]. Binocular and Monocular methods tend to fail when using triangulation on homogeneous regions due to a depletion of separable landmarks [89]. Lucesoli et al [90] propose endoscopic single-point laser distance sensing, to measure the distance between the endoscope and the surface.…”
Section: Laser Distance Sensingmentioning
confidence: 99%
See 1 more Smart Citation
“…To analyze the frequencies and determine the distance to the surface, a Fourier transform is used [88]. Binocular and Monocular methods tend to fail when using triangulation on homogeneous regions due to a depletion of separable landmarks [89]. Lucesoli et al [90] propose endoscopic single-point laser distance sensing, to measure the distance between the endoscope and the surface.…”
Section: Laser Distance Sensingmentioning
confidence: 99%
“…The results of the trinocular setup are compared to a binocular setup running an SGBM algorithm [140] from the OpenCV library. Conen and Luhmann [89] determine the MAE to the ground truth for the trinocular setup to be 0.29 mm with a SD of 1.14 mm, while the trinocular endoscope is positioned 210 mm away from the object. For the binocular setup, the authors record an MAE to the ground truth of 0.21 mm with a SD of 1.48 mm for the same distance setup.…”
Section: Trinocular Endoscopementioning
confidence: 99%
“…Recent publications describe advanced localization and real time tracking techniques based on these. Examples include the use of optical models for improvements in accuracy of endoscopic measurements [8], photogrammetry for obtaining 3D maps on a larger scale [3], [4] or approaches for localizing the probe relatively against the inner spaces using triangulation and other optical solutions [11] or even using shape sensing of the hose itself [14]. Additionally, some authors have claimed applications in microscopy using endoscopes [9].…”
Section: Endoscopymentioning