2007
DOI: 10.1007/s10096-007-0311-7
|View full text |Cite
|
Sign up to set email alerts
|

Outbreak of Achromobacter xylosoxidans pseudobacteremia in a neonatal care unit related to contaminated chlorhexidine solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
23
0

Year Published

2011
2011
2025
2025

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(25 citation statements)
references
References 10 publications
0
23
0
Order By: Relevance
“…was not demonstrated herein, and the isolates presented a potential tolerance to chlorhexidine, which is the most used antiseptic in odontology. Resistance of Achromobacter xylosoxidans to chlorhexidine has been previously demonstrated in two cases of infections caused by the use of contaminated chlorhexidine solution to disinfect the patient's skin or medical devices (38)(39)(40).…”
Section: Discussionmentioning
confidence: 99%
“…was not demonstrated herein, and the isolates presented a potential tolerance to chlorhexidine, which is the most used antiseptic in odontology. Resistance of Achromobacter xylosoxidans to chlorhexidine has been previously demonstrated in two cases of infections caused by the use of contaminated chlorhexidine solution to disinfect the patient's skin or medical devices (38)(39)(40).…”
Section: Discussionmentioning
confidence: 99%
“…It is also a prevalent nosocomial colonizer and has been isolated from multiple types of aqueous solutions found in the health care setting, such as nonbacteriostatic saline (24), dialysis solutions (33), contact lens solutions (15), intravenous CT contrast solutions (32), chlorhexidine gluconate solutions (35), and ultrasound gel (28). A. xylosoxidans also colonizes fomites such as mechanical ventilators (6), neonatal incubators (25,29), faucet aerators (17,43), intravenous catheters (1,17,20,24), epidural catheters (30), urinary catheters (29), intravascular pressure transducers (17), pacemaker leads (2,26,33,36), and extracorporeal membrane oxygenation machines (21).…”
Section: Case Reportmentioning
confidence: 99%
“…To date, in hospitals, A. xylosoxidans has been involved in many procedure-related infections, being associated for instance with contaminated disinfectants (17), dialysis fluids (7), and ultrasound gel (18). There are a few reports of A. xylosoxidans being found in outdoor environments, including in some plants (19,20), in polluted soils (21,22), and in an indoor swimming pool (23).…”
mentioning
confidence: 99%