Abstract: Summary This paper aims at specifying the optimal allocation of a hybrid supercapacitor‐vanadium redox flow battery (VRB) energy storage system (ESS) for maintaining power balance of active distribution networks (ADNs) for wind power applications. Correspondingly, an optimal allocation approach for the hybrid ESS considering the application scenarios of supercapacitor ESS and VRB ESS was proposed. The supercapacitor ESS was used for restraining the high‐frequency components of net load power and a net load pow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(13 citation statements)
references
References 40 publications
0
13
0
Order By: Relevance
“…. e velocity and position of the particles are then updated according to (17) and (18) [24,25] as Figure 8:…”
Section: Computational Intelligence and Neurosciencementioning
confidence: 99%
See 1 more Smart Citation
“…. e velocity and position of the particles are then updated according to (17) and (18) [24,25] as Figure 8:…”
Section: Computational Intelligence and Neurosciencementioning
confidence: 99%
“…Converters are able to convert power from AC bus to DC bus. The bidirectional converter is expressed as follows [ 17 ]: …”
Section: Mathematical Modelmentioning
confidence: 99%
“…The installation rooftop PV installation is a contemporary form of distributed generation wherein customers are equipped with 2 of 16 generation and selling of electric power as well, forming a bi-directional power flow from conventional load buses [7]. Consequently, this type of decentralized power generation will explicitly limit the controllability of power flow and as a result, the system will be vulnerable to voltage violation and other power quality issues [8]. Henceforth, the concept of an energy storage system (ESS) has been adopted to provide ancillary support for optimal generation, transmission and demand side management [9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…Because WTPC models are determined by the model parameters, parameter estimation methods have been widely studied. As shown in previous studies, [10][11][12] the least-square methods were usually employed to estimate parameters of WTPCs. However, prior knowledge about these estimated parameters are required, and improper parameter initializations may lead to non-optimal solutions.…”
Section: Introductionmentioning