2022
DOI: 10.48550/arxiv.2205.00005
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Optically detected magnetic resonance with an open source platform

Abstract: Localized electronic spins in solid-state environments form versatile and robust platforms for quantum sensing, metrology and quantum information processing. With optically detected magnetic resonance (ODMR), it is possible to prepare and readout highly coherent spin systems, up to room temperature, with orders of magnitude enhanced sensitivities and spatial resolutions compared to induction-based techniques, allowing single spin manipulations. While ODMR was first observed in organic molecules, many other sys… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 118 publications
0
5
0
Order By: Relevance
“…Both photoluminescence and ODMR measurements were carried out in our home-built confocal fluorescence microscope. More information about the setup and the acquisition software can be found in 78 . In order to achieve sufficiently high spatial resolution we use a high numerical aperture objective (N.A.= 0.9) and we collect the signal with a single mode fiber and a single photon detector.…”
Section: Methodsmentioning
confidence: 99%
“…Both photoluminescence and ODMR measurements were carried out in our home-built confocal fluorescence microscope. More information about the setup and the acquisition software can be found in 78 . In order to achieve sufficiently high spatial resolution we use a high numerical aperture objective (N.A.= 0.9) and we collect the signal with a single mode fiber and a single photon detector.…”
Section: Methodsmentioning
confidence: 99%
“…The relaxometry protocol used with the widefield setup is very similar to the typical sequence used in an NV center confocal setup. 21 It consists of a polarization pulse that pumps all the NV centers to the m s = 0 state, followed by a readout pulse that allows for the detector to read the current state population of the NV centers. However, the counts we detect are not completely zero when the light source is off.…”
Section: T 1 Relaxometrymentioning
confidence: 99%
“…Both photoluminescence and ODMR measurements were carried out in our home-built confocal fluorescence microscope. More information about the setup and the acquisition software can be found in [69]. In order to achieve sufficiently high spatial resolution we use a high numerical aperture objective (N.A.= 0.9) and we collect the signal with a single mode fiber and a single photon detector.…”
Section: Pl and Odmr Measurementsmentioning
confidence: 99%