Abstract: Biosensors for continuous glucose monitoring in bioreactors could provide a valuable tool for optimizing culture conditions in biotechnological applications. We have developed an optical biosensor for long-term continuous glucose monitoring and demonstrated a tight glucose level control during cell culture in disposable bioreactors. The in-line sensor is based on a commercially available oxygen sensor that is coated with cross-linked glucose oxidase (GOD). The dynamic range of the sensor was tuned by a hydroph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 40 publications
(24 citation statements)
references
References 31 publications
0
24
0
Order By: Relevance
“…In addition, glucose monitoring has been widely applied in the food industry as a quality control and safety tool [12]. Another application is cell culture: Because glucose is a primary carbon source for proliferating mammalian cells, glucose quantification provides valuable information on metabolism [13][14][15]. Methods for glucose monitoring in cell culture include Raman spectroscopy, liquid chromatography, and other spectroscopic techniques; in general, these techniques are expensive and time-consuming [16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, glucose monitoring has been widely applied in the food industry as a quality control and safety tool [12]. Another application is cell culture: Because glucose is a primary carbon source for proliferating mammalian cells, glucose quantification provides valuable information on metabolism [13][14][15]. Methods for glucose monitoring in cell culture include Raman spectroscopy, liquid chromatography, and other spectroscopic techniques; in general, these techniques are expensive and time-consuming [16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, an optical fiber sensor for glucose was developed by modifying the surface of a commercially available oxygen sensor (OXY-4 mini ® PreSens, Regensburg, Germany) with crosslinked glucose oxidase. The results of the sensor integrated into the BR showed good durability of the sensor for a period of 52 days, linear characteristics up to 20 mM and the sensor's response time lower than 10 min [248].…”
Section: Electrochemical Biosensors For Nutrients and Metabolitesmentioning
confidence: 96%
“…Different principles of glucose sensors based on electrochemical and optical detection were recently proposed in the literature for application in BRs [247][248][249][250][251][252][253][254][255][256][257]. The innovative combination of droplet microfluidics and optical detection methods was proposed by Adams and coworkers for rapid measurements of glucose levels in the µBR systems [247].…”
Section: Electrochemical Biosensors For Nutrients and Metabolitesmentioning
confidence: 99%
“…We previously developed an optical glucose biosensor capable of in‐line glucose measurements [ 9 ] and its manufacture was described in detail. [ 10 ] The ease of handling and disposable feature of this sensor enables integration into various cultivation systems for single‐use glucose monitoring.…”
Section: Introductionmentioning
confidence: 99%