2017
DOI: 10.1007/s10967-017-5342-7
|View full text |Cite
|
Sign up to set email alerts
|

On neutron activation analysis with γγ coincidence spectrometry

Abstract: A new γγ coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0
4

Year Published

2018
2018
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 17 publications
0
0
0
4
Order By: Relevance
“…Os estudos sobre a eficiência de detecção para 2 e 4 detectores, assim como os resultados das concentrações obtidos pelas duas metodologias (CINAA e INAA) foram publicados no Journal of Radioanalitical and Nuclear Chemistry com o título de ""On neutron activation analysis with γγ coincidence spectrometry" [47].…”
Section: Resultados Obtidos No Nistunclassified
See 2 more Smart Citations
“…Os estudos sobre a eficiência de detecção para 2 e 4 detectores, assim como os resultados das concentrações obtidos pelas duas metodologias (CINAA e INAA) foram publicados no Journal of Radioanalitical and Nuclear Chemistry com o título de ""On neutron activation analysis with γγ coincidence spectrometry" [47].…”
Section: Resultados Obtidos No Nistunclassified
“…Para minimizar os efeitos gerados pelo espalhamento Compton alguns pesquisadores utilizam supressores Compton [39,40,45]. No entanto, medidas em CINAA podem diminuir o contínuo do espectro gerado pelo espalhamento Compton em virtude de apenas eventos coincidentes serem registrados (note que os eventos provenientes de espalhamento Compton em coincidência com os fótons que se deseja medir estarão presentes), conforme já demonstrado por Goto et al [40]; Meyer [24] e Zeisler et al [47].…”
Section: Efeito Comptonunclassified
See 1 more Smart Citation
“…A fim de minimizar estas limitações, a separação radioquímica e a contagem são utilizadas na espectrometria de raios gama. Um método de medição para esses casos é a espectrometria em coincidência γ−γ (ZEISLER, et. al, 2017).…”
unclassified