2017
DOI: 10.1016/j.talanta.2017.05.038
|View full text |Cite
|
Sign up to set email alerts
|

On-line gaseous formaldehyde detection by a microfluidic analytical method based on simultaneous uptake and derivatization in a temperature controlled annular flow

Abstract: This paper is focused on the improvement of a microfluidic analytical method for the detection of low airborne formaldehyde concentrations, based on only two distinct steps permitting to reduce the response time and to improve the compactness of the device. First, gaseous formaldehyde is trapped into an acetylacetone solution at 65°C through an annular liquid/gas flow and reacts immediately to form 3,5-Diacetyl-1,4-dihydrolutidine which is then quantified by colorimetry using a liquid core waveguide (LCW). To … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
32
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(33 citation statements)
references
References 35 publications
(41 reference statements)
1
32
0
Order By: Relevance
“…Similar conclusions were found for formaldehyde measurements with a dedicated analyzer and then modeled. Monoterpenes are overestimated by a factor of 3.5 using the PTR‐ToF‐MS emission measurements, whereas the GC emission rate measurements without the camphene (coeluted with 124 TMB) satisfactorily reproduce the indoor profiles.…”
Section: Resultssupporting
confidence: 82%
“…Similar conclusions were found for formaldehyde measurements with a dedicated analyzer and then modeled. Monoterpenes are overestimated by a factor of 3.5 using the PTR‐ToF‐MS emission measurements, whereas the GC emission rate measurements without the camphene (coeluted with 124 TMB) satisfactorily reproduce the indoor profiles.…”
Section: Resultssupporting
confidence: 82%
“…The objectives of this study are two-fold: firstly, to provide experimental data on the temporal variations of aldehydes concentrations in a Low-Energy building, and secondly, to test, under real conditions, a new formaldehyde analyzer which has already been validated by previous laboratory studies [17,18]. Therefore, this work reports formaldehyde and aldehydes measurements in indoor air for two weeks during the MERMAID intensive field campaign performed in a junior high school recently built according to the French thermal regulation of 2005.…”
Section: Of 19mentioning
confidence: 99%
“…The analytical method recently developed in our laboratory was already detailed in our previous studies [17,18]. As shown in Figure 1, this analytical method is also based on three highly coupled steps: (1) the uptake of gaseous formaldehyde into an aqueous acetylacetone solution at room temperature;…”
Section: Formaldehyde Microanalyzer Based On a Microfluidic Devicementioning
confidence: 99%
See 2 more Smart Citations