1963
DOI: 10.1002/jsfa.2740141014
|View full text |Cite
|
Sign up to set email alerts
|

Odour thresholds of some organic compounds associated with food flavours

Abstract: A simple technique for measurement of olfactory thresholds of odorous materials is described. Sensitivity and reproducibility of the method was good, but many precautions must be taken to insure reliability of results. Olfactory thresholds for a number of pure compounds, several of which were identified in potatoes, are presented. In general, sulphur compounds and short-chain unsaturated aldehydes gave the lowest and highest thresholds, respectively. The thresholds of a homologous series of saturated aliphatic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
121
1
3

Year Published

1989
1989
2014
2014

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 226 publications
(127 citation statements)
references
References 3 publications
2
121
1
3
Order By: Relevance
“…The theoretical odor unit (Guadagni et al, 1963;Nursten, 1979) represented by the quotient of threshold value and concentration is applicable only in cases where all the compositions in a given sample are preliminarily identified. The threshold value may, however, be impossible to determine unless the authentic compound is available.…”
Section: Resultsmentioning
confidence: 99%
“…The theoretical odor unit (Guadagni et al, 1963;Nursten, 1979) represented by the quotient of threshold value and concentration is applicable only in cases where all the compositions in a given sample are preliminarily identified. The threshold value may, however, be impossible to determine unless the authentic compound is available.…”
Section: Resultsmentioning
confidence: 99%
“…In the initial work performed by the Flavor Research Group at the US Department of Agriculture Western Regional Research Center in Albany, CA, Guadagni, Buttery and co-workers found better reproducibility and lower thresholds when odorants were presented directly to the nostril with a squeeze sniff bottle, as compared to the standard sniffing technique of a glass vial headspace. 35 Thresholds were 1.2 (propanal) to 98 (nonanal) times lower with the sniff bottle as compared to the vial headspace. It is interesting to note that for decanal, the threshold value from the same laboratory, but using different panelists and Teflon bottles instead of polyethylene bottles, resulted in a threshold 20 times higher, 2 ppb vs. 0.1 ppb, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…To determine the sensory threshold values of taste in aqueous solution the method developed by GUA-DAGNI et al [9] and called dilution technique, was used, complemented by asking for the description of taste belonging to a given concentration. The model solutions were diluted with ion-free water, filtered through active carbon (Aquapure FD).…”
Section: Methodsmentioning
confidence: 99%