2011
DOI: 10.1016/j.ijhydene.2011.06.024
|View full text |Cite
|
Sign up to set email alerts
|

Numerical simulation of the hydrogen storage with reaction heat recovery using metal hydride in the totalized hydrogen energy utilization system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
10
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 28 publications
3
10
0
Order By: Relevance
“…The permeability of the metal hydride bed with an average particle diameter equal to 10 -5 is 7.5·10 -13 . This value lies within the range of values that can be found in the literature (from 4.5·10 -15 m 2 [19] to 10 -12 m 2 in [20]). The permeability of the aluminium foam is equal to 10 -7 (from 0.3·10 -7 m 2 to 14.2·10 -7 m 2 in [21]).…”
Section: Mathematical Modelsupporting
confidence: 86%
“…The permeability of the metal hydride bed with an average particle diameter equal to 10 -5 is 7.5·10 -13 . This value lies within the range of values that can be found in the literature (from 4.5·10 -15 m 2 [19] to 10 -12 m 2 in [20]). The permeability of the aluminium foam is equal to 10 -7 (from 0.3·10 -7 m 2 to 14.2·10 -7 m 2 in [21]).…”
Section: Mathematical Modelsupporting
confidence: 86%
“…The recovery rate in the continuous 24 hours cycle experiment results was 46.3% during the absorption process and 44.4% during the desorption process, and that in the simulation results was 50.4% and 44%, respectively, indicating that the simulation results were within the experimental error. These comparison results validate the simulation code [2]. …”
Section: -Hour Cycle Comparison Experiments and Simulationsupporting
confidence: 76%
“…In terms of temperature conditions, we assumed that the reaction heat in the absorption process was cooled with a typical cooling tower, and set the temperature of the circulating water to be less than 32 ºC, based on the temperature of the cooling tower at midsummer peak. On the other hand, the temperature of the circulating water during the hydrogen desorption process was set to 12 ºC to enable air-conditioning [2]- [4]. The performance of the metal hydride tank was numerically evaluated here for THEUS operation aimed at load leveling [2].…”
Section: Purpose Of Theus and Metal Hydride Tankmentioning
confidence: 99%
See 2 more Smart Citations