2007
DOI: 10.1007/s10665-007-9165-3
| |Summarize |Cite
|
Sign up to set email alerts

Numerical gradient methods for flux identification in a system of conservation laws

Abstract: International audienceThe identification of the flux for a system of conservation laws is studied from a numerical point of view, on the specific example of chromatography. Different strategies to compute the exact gradient of the discretized optimization problem are developed and compared. Numerical evidence of the convergence of the method is also given in the scalar and binary case. Finally a ternary mixture with real experimental data is studied and the identified isotherm is compared with chemical enginee… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
5
4
0
0

Citation Types

0
14
0
0

Year Published

Range
2007
2007
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

Cited by 8 publications

(14 citation statements)

References 25 publications

0
14
0
0
Order By: Relevance
How the paper below cites the one you are viewing
“…Furthermore, there seems to be no need, when using CMA-ES, to fix the 3 Langmuir coefficients in order to find good results: when optimizing all 6 parameters, the gradient approach could not reach a value smaller than 0.01, whereas the best fitness found by CMA-ES in the same context is 8.32 10 −3 (Table III). Finally, when comparing the identified isotherms to the experimental ones (figure 6), the fit is clearly not very satisfying (similar deceptive results were obtained with the gradient method in [12]): Fitting both the isotherms and the chromatograms seem to be contradictory objectives. Two directions can lead to some improvements in this respect: modify the cost function J in order to take into account some least-square error on the isotherm as well as on the [12].…”
Section: Comparison With a Gradient Methods
mentioning
confidence: 75%
“…Finally, when comparing the identified isotherms to the experimental ones (figure 6), the fit is clearly not very satisfying (similar deceptive results were obtained with the gradient method in [12]): Fitting both the isotherms and the chromatograms seem to be contradictory objectives. Two directions can lead to some improvements in this respect: modify the cost function J in order to take into account some least-square error on the isotherm as well as on the [12]. chromatograms; or use a multi-objective approach.…”
Section: Comparison With a Gradient Methods
mentioning
confidence: 75%
“…CMA-ES results have then been compared with those of the gradient method from [12], using the same data case of ternary mixture taken from [10] and described in previous Section. Chromatograms found by CMA-ES are, according to the fitness (see Tables II and III), closer to the experimental ones than those obtained with the gradient method.…”
Section: Comparison With a Gradient Methods
mentioning
confidence: 99%
“…Two series of numerical tests have been performed using a gradient-based method [12]: identification of the whole set of 6 parameters, and identification of the 3 saturation coefficients N * i only, after setting the Langmuir coefficients to the experimentally measured values (K Comparisons between the two experimental chromatograms and those resulting from CMA-ES identification for the two experiments are shown in Figure 5, for the 6-parameters case. The corresponding plots in the 3-parameters case are visually identical though the fitness value is slightly lower than in the 6-parameters case (see Tables II and III).…”
Section: B Experiments On Real Data
mentioning
confidence: 99%
“…ASSOCIATED TO PARAMETERS VALUES OF TABLE III (CONTINUOUS LINE) AND EXPERIMENTAL ONES (MARKERS) VERSUS TOTAL AMOUNT OF THE MIXTURE FOR DIFFERENT PROPORTIONS OF THE COMPONENT IN THE INJECTED CONCENTRATION[12].…”
mentioning
confidence: 99%
See 4 more Smart Citations