New scenarios in human trunk posture measurements for clinical applications

Abstract: Abstract-It is well established how maintaining a correct body posture is absolutely fundamental to prevent skeleton and muscular pathologies. For instance the trunk's postures assumed in a typical working day for who spends many hours in front of a pc-screen, or the typical motion behaviour in the classroom routine for the pupils, can even lead to some body handicaps. Accordingly, it appears obvious how the exact evaluation of assumed postures during the possible daily activities is the starting point for the… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
25
6
4
1

Citation Types

0
21
0
0

Year Published

Range
2011
2011
2026
2026

Publication Types

Select...
19
6
5
2

Relationship

8
24

Authors

Journals

Cited by 32 publications

(21 citation statements)

References 8 publications

0
21
0
0
Order By: Relevance
How the paper below cites the one you are viewing
“…The four contributions stated in the Introduction were validated as follows: (1) The dual-purpose cable architecture achieved a mean tracking error of 2.66°(SD 1.16°, N = 10, 2500 OptiTrackreferenced cycles), comparable to the ±5°reported for flex-sensor gloves [6,8] and below the 3°t hreshold for rigid-object grasping. (2) The dual-mode calibration system produced a non-linearity of 1.8% full scale, adequate for the linear calibration mapping.…”
Section: Discussion
mentioning
confidence: 99%
“…First, the single-tendon dualfunction architecture eliminates the need for separate sensing and actuation linkages, halving cable runs relative to [19] and reducing assembly complexity. Second, rotary potentiometers provide monotonic, low-hysteresis angle measurement without the drift and fatigue documented for flex sensors in [6,8] and at a unit cost below USD 1. Third, the BLE GATT interface decouples the glove from the host platform, enabling standalone operation on Meta Quest headsets without a tethered PC, which is a prerequisite for scalable deployment in educational and training environments [32].…”
Section: Discussion
mentioning
confidence: 99%
“…Tracking accuracy. NEC Hands achieves ±2.7°mean error, which is roughly twice that of SenseGlove (±1.5°) and HaptX (<1°), but approximately half the error of typical flex-sensor gloves (±5°) [6]. The difference is attributable to the single-MCP-axis measurement and the mechanical compliance of the string linkage; commercial systems use multi-axis magnetic or Hall-effect sensing with rigid linkages.…”
Section: Comparison With Existing Systems
mentioning
confidence: 94%
See 2 more Smart Citations