2021
DOI: 10.1016/j.thromres.2021.02.007
|View full text |Cite
|
Sign up to set email alerts
|

Nephrotic syndrome disease activity is proportional to its associated hypercoagulopathy

Abstract: doi: medRxiv preprint NOTE: This preprint reports new research that has not been certified by peer review and should not be used to guide clinical practice.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
41
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 13 publications
(41 citation statements)
references
References 74 publications
(108 reference statements)
0
41
0
Order By: Relevance
“…Key NS patient demographic features in the NEPTUNE, PNRC, and Columbus cohorts are summarized in Table 2, additional details were previously published. 10,11 AT deficiency was observed in all 3 cohorts such that AT antigen and/or activity <70% (<0.7 IU/mL) was observed in 71%, 95%, and 52% of the NEPTUNE, PNRC, and Columbus patients, respectively. AT relationships with plasma albumin, UPCR, and ETP are shown for the NEPTUNE, PNRC, and Columbus cohorts in Figures 1, 2, and S3, respectively.…”
Section: Nephrotic Syndrome Patientsmentioning
confidence: 95%
See 4 more Smart Citations
“…Key NS patient demographic features in the NEPTUNE, PNRC, and Columbus cohorts are summarized in Table 2, additional details were previously published. 10,11 AT deficiency was observed in all 3 cohorts such that AT antigen and/or activity <70% (<0.7 IU/mL) was observed in 71%, 95%, and 52% of the NEPTUNE, PNRC, and Columbus patients, respectively. AT relationships with plasma albumin, UPCR, and ETP are shown for the NEPTUNE, PNRC, and Columbus cohorts in Figures 1, 2, and S3, respectively.…”
Section: Nephrotic Syndrome Patientsmentioning
confidence: 95%
“…Plasma albumin was quantified using a bromocresol purple assay kit according to the manufacturer's instructions (BioAssay Systems, Hayward, CA), as previously described. 10,39 Coagulation Parameters Thrombin generation assays were performed using Technothrombin TGA kits (Technoclone, Vienna, Austria) and TGA RC Low reagent, read on a Spectramax M2 fluorescent plate reader (Molecular Devices, Sunnyvale, California), as previously described. 10,11,15 TGA generates several hemostasis parameters, including endogenous thrombin potential (ETP), that may be indicative of hypercoagulopathy.…”
Section: Study Subjectsmentioning
confidence: 99%
See 3 more Smart Citations