2020
DOI: 10.1117/1.oe.59.6.061616
|View full text |Cite
|
Sign up to set email alerts
|

Near-infrared autofluorescence spectroscopy of pigmented benign and malignant skin lesions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
15
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 17 publications
1
15
0
Order By: Relevance
“…The spectral differences in the 800-870 nm region not exceed 5.9%. Both mean AMM and PMM spectra have spectral maxima at 840 and 865 nm in comparison with normal skin and other skin tumors such as BCC [12]. In our previous studies, we have mentioned that local maxima at 840 and 865 nm are observed in the spectra of tumors with high melanin concentration [12].…”
Section: Resultsmentioning
confidence: 82%
See 3 more Smart Citations
“…The spectral differences in the 800-870 nm region not exceed 5.9%. Both mean AMM and PMM spectra have spectral maxima at 840 and 865 nm in comparison with normal skin and other skin tumors such as BCC [12]. In our previous studies, we have mentioned that local maxima at 840 and 865 nm are observed in the spectra of tumors with high melanin concentration [12].…”
Section: Resultsmentioning
confidence: 82%
“…Both mean AMM and PMM spectra have spectral maxima at 840 and 865 nm in comparison with normal skin and other skin tumors such as BCC [12]. In our previous studies, we have mentioned that local maxima at 840 and 865 nm are observed in the spectra of tumors with high melanin concentration [12]. These peaks are shifted to longer wavenumber region that causes overlapping of Raman peaks at 1086 ( υ !…”
Section: Resultsmentioning
confidence: 93%
See 2 more Smart Citations
“…Although the spectrum acquisition time is 60 s for a low‐cost system and about 1 s (or even less) for the devices with deeply cooled detectors, the accuracy of automatic analysis with the proposed system is higher than the accuracy of GPs and trainees, and is comparable or less to the accuracy of trained dermatologists. An important feature of the proposed approach is that it may be easily combined with other optical techniques of skin lesions analysis, such as dermoscopy‐ and spectroscopy‐based CAD systems 49,50 or application of AF analysis in the visible region 52‐55 and/or analysis of the diffuse reflectance in the visible and NIR regions 56‐59 . Neoplasms colour estimation is problematic with the proposed spectroscopic setup, and NIR spectral analysis may be complemented with neoplasms images analysis.…”
Section: Discussionmentioning
confidence: 99%