2018
DOI: 10.5101/nbe.v10i1.p34-39
|View full text |Cite
|
Sign up to set email alerts
|

Nanoparticles of TiO2-ZnO Modified Polystyrene-Acrylonitrile Characterization Using Glassy Carbon Electrode

Abstract: Grafted polystyrene with acrylonitrile modified nanoparticles of TiO 2 -ZnO was successfully prepared to study its electrochemical characterization by cyclic voltammetric (CV) method. It was found the new modified copolymer had good electrochemical properties and was a semi-conductor material. The ratio redox current peak (Ipa/Ipc) was equal to 2; the separation potential peak (Epa-Epc) was equal to 113 mV. Normal saline was used as a good electrolyte to enhance the solution of peaks of redox current for K 4 F… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…The influence of different temperatures on the new fabrication electrode was used the redox current peaks value of output potential using K 4 The activation energy which needed to oxidizing the Fe(II) to Fe(III) was found as E*=1.05 kJmol -1 K -1 with less value than using other electrodes such as grafted polymer electrode in the same operation as E*=1.75kJmol -1 K -1 [30]. Also, the stability of GPE at high temperature has high resistance than other working electrodes [31][32][33][34][35][36][37][38].…”
Section: The Influence Of Different Temperatures On the Cesmc 60mentioning
confidence: 99%
“…The influence of different temperatures on the new fabrication electrode was used the redox current peaks value of output potential using K 4 The activation energy which needed to oxidizing the Fe(II) to Fe(III) was found as E*=1.05 kJmol -1 K -1 with less value than using other electrodes such as grafted polymer electrode in the same operation as E*=1.75kJmol -1 K -1 [30]. Also, the stability of GPE at high temperature has high resistance than other working electrodes [31][32][33][34][35][36][37][38].…”
Section: The Influence Of Different Temperatures On the Cesmc 60mentioning
confidence: 99%
“…11 illustrates the SEM of the GP structure with silica nanoparticles. The silica nanoparticles were incorporated inside the GP structure [22][23][24][25][26].…”
Section: Effect Of Different Scan Ratesmentioning
confidence: 99%
“…I-motif and anti-cancer drugs were studied by electrochemical techniques by using CV and differential pulse voltammetry (DPV) methods to determine and characterize saffron carotenoids on the modified electrode for treatment of the drugs [10,11]. Three natural drugs of crocin, kaempferol and podophyllotoxin were evaluated as antioxidant medicine by cyclic voltammetric technique using multi-walled carbon nanotube paste electrode (MWCNTPE) at acidic pH 4.5.…”
Section: Introductionmentioning
confidence: 99%