Abstract: Purpose To present a novel multisource rotating shield brachytherapy (RSBT) apparatus for the simultaneous precise angular and linear positioning of partially-shielded 153Gd brachytherapy sources in interstitial needles for the treatment of locally-advanced prostate cancer. It is designed to lower the dose to nearby healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods and Materials Following needle implantation through the patient temp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
27
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 12 publications
(27 citation statements)
references
References 43 publications
0
27
0
Order By: Relevance
“…When used in combination with external beam radiotherapy (EBRT) in the form of a boost, high‐dose rate (HDR) brachytherapy has been shown to be a safe and effective treatment modality for intermediate‐ and high‐risk prostate cancer . Despite recent technological developments in the field of brachytherapy, such as image‐guided brachytherapy, treatment planning, electromagnetic tracking, and applicator development, poor execution of HDR prostate brachytherapy can still have a significant effect on patient outcomes. Furthermore, the incidences of errors that may occur in the practice of HDR prostate brachytherapy is relatively unknown, and limited options exist for independent routine monitoring of treatment delivery.…”
Section: Introductionmentioning
confidence: 99%
“…When used in combination with external beam radiotherapy (EBRT) in the form of a boost, high‐dose rate (HDR) brachytherapy has been shown to be a safe and effective treatment modality for intermediate‐ and high‐risk prostate cancer . Despite recent technological developments in the field of brachytherapy, such as image‐guided brachytherapy, treatment planning, electromagnetic tracking, and applicator development, poor execution of HDR prostate brachytherapy can still have a significant effect on patient outcomes. Furthermore, the incidences of errors that may occur in the practice of HDR prostate brachytherapy is relatively unknown, and limited options exist for independent routine monitoring of treatment delivery.…”
Section: Introductionmentioning
confidence: 99%
“…The brachytherapy dose to the urethra is the most important predictor of long-term GU morbidity. [12][13][14] The low rate of toxicity for HDR BT monotherapy delivered in a single fraction of 19 Gy suggests that dose escalation may be beneficial, since local control rates are too low. 2 Further dose escalation to 21 Gy or more is currently limited by urethral dose constraints.…”
Section: Introductionmentioning
confidence: 99%
“…Intensity modulated brachytherapy (IMBT) is a novel brachytherapy technique which incorporates static or dynamic shields inside needles or applicators to direct the radiation toward the tumor and away from healthy tissues. [15][16][17] IMBT has been investigated for prostate, [18][19][20] cervical, [21][22][23][24][25][26] and rectal cancers. 27,28 In the case of prostate cancer, IMBT has the capability to reduce the dose delivered to nearby radiation sensitive healthy tissues, such as the urethra, or allow for dose escalation without an associated increase in urethral dose for monotherapy.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…"Dynamic" IMBT encompasses techniques in which the shield changes orientation relative to the source or tissue during treatment. Such approaches include rotating-shield brachytherapy (RSBT) [65][66][67][68][69][70][71][72][73][74][75][76][77][78][79][80] and dynamic modulated brachytherapy (DMBT). 24,25 In this study, we conduct a systematic review of the IMBT literature and then analyze the investigations by disease site, technique, planning algorithm, and study type.…”
Section: Introductionmentioning
confidence: 99%