2017
|
Sign up to set email alerts
Multiple uses of fibrin sealant for nervous system treatment following injury and disease
Abstract: Lesions to the nervous system often produce hemorrhage and tissue loss that are difficult, if not impossible, to repair. Therefore, scar formation, inflammation and cavitation take place, expanding the lesion epicenter. This significantly worsens the patient conditions and impairment, increasing neuronal loss and glial reaction, which in turn further decreases the chances of a positive outcome. The possibility of using hemostatic substances that also function as a scaffold, such as the fibrin sealant, reduces … Show more
Search citation statements
Order By: Relevance
Paper Sections
Select...
51
18
8
4
Citation Types
0
49
0
0
Year Published
Range
2017
20172026
2026Publication Types
Select...
56
13
5
2
Relationship
21
55
Authors
Journals
Cited by 76 publications
(49 citation statements)
References 133 publications
0
49
0
0
Order By: Relevance
Smart CitationsHow the paper below cites the one you are viewing
“…The two components usually contain added plasmatic proteins such as factor XIII, fibronectin, and an anti-fibrinolytic agent like aprotinin or tranexamic acid [ 7 ]. Nowadays, aprotinin-free and tranexamic acid-free formulations are available [ 3 , 5 ] reducing the risk of side effects, such as aprotinin-associated hypersensitivity reactions, and tranexamic acid-associated neurotoxicity [ 3 , 5 , 20 – 23 ]. Several adhesives are available as liquid formulations (Evicel®, Crosseal™, Quixil®, Floseal®, Surgiflo®, Tisseel®, Beriplast P®) or as medicated sponge/patch (Tachosil®, Evarrest®).…”
Section: Results
mentioning
confidence: 99%
“…Liquid fibrin adhesives are also effective as sealants, an adjunctive measure which improves the watertight closure of the dural suture line thus preventing cerebrospinal fluid leak (CSF) [ 20 – 23 ]. Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity.…”
Section: Results
mentioning
confidence: 99%
“…Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity. In fact, some evidence from preclinical studies has shown that tranexamic acid induced hyperexcitability and convulsions, probably caused by blocking GABA-mediated inhibition in the central nervous system [ 1 , 20 – 23 ].…”
Section: Results
mentioning
confidence: 99%
“…Routine use of TachoSil® patch to prevent pancreatic fistulas does not provide clinically significant benefit. | 1C | | Perussi Biscola et al [ 20 ] | 2017 | Systematic review | The new heterologous fibrin sealant from snake venom represents a consistent alternative to biological sealants, since they may avoid transmission of infectious diseases | 1C |
| Pommergaard et al [ 26 ] | 2013 | Systematic review | Liquid fibrin adhesive should be beneficial to prevent leak of ileal anastomoses in gastric and bariatric surgery | 1C |
| Saha et al [ 9 ] | 2012 | Prospective randomized | Fibrin sealant is safe and its efficacy is superior to manual compression for hemostasis in patients with vascular ePTFE graft | 1C |
| Schwartz et al [ 6 ] | 2004 | Prospective randomized controlled | Crosseal fibrin sealant significantly reduces the time of hemostasis following liver resection in comparison with the standard topical hemostatic agents | 1C |
| Simo et al [ 15 ] | 2012 | Systematic review | Application of TachoSil® in hepatobiliary and pancreatic surgery has proven effectiveness in hemostasis and as tissue sealant | 1C |
| Spotniz et al [ 7 ] | 2012 | Systematic review | Fibrin sealants have multiple new uses that should result in further improvement in patient care | 1C |
| Taylor et al[ 8 ] | 2003 | Randomized prospective multicenter | Fibrin sealants are more effective than thrombin-soaked gelatin sponge for achieving hemostasis of needle or suture hole bleeding from PTFE femoral artery grafts. | 1B |
| Vakalopoulos et al [ 25 ] | 2012 | Systematic review | Fibrin sealant seem not be necessary as external coating of colonic anastomoses to prevent leakage | 1C |
…”
Section: Results
mentioning
confidence: 99%
Abstract
Smart CitationsHow the paper below cites the one you are viewing
“…The two components usually contain added plasmatic proteins such as factor XIII, fibronectin, and an anti-fibrinolytic agent like aprotinin or tranexamic acid [ 7 ]. Nowadays, aprotinin-free and tranexamic acid-free formulations are available [ 3 , 5 ] reducing the risk of side effects, such as aprotinin-associated hypersensitivity reactions, and tranexamic acid-associated neurotoxicity [ 3 , 5 , 20 – 23 ]. Several adhesives are available as liquid formulations (Evicel®, Crosseal™, Quixil®, Floseal®, Surgiflo®, Tisseel®, Beriplast P®) or as medicated sponge/patch (Tachosil®, Evarrest®).…”
Section: Results
mentioning
confidence: 99%
“…Liquid fibrin adhesives are also effective as sealants, an adjunctive measure which improves the watertight closure of the dural suture line thus preventing cerebrospinal fluid leak (CSF) [ 20 – 23 ]. Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity.…”
Section: Results
mentioning
confidence: 99%
“…Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity. In fact, some evidence from preclinical studies has shown that tranexamic acid induced hyperexcitability and convulsions, probably caused by blocking GABA-mediated inhibition in the central nervous system [ 1 , 20 – 23 ].…”
Section: Results
mentioning
confidence: 99%
“…Routine use of TachoSil® patch to prevent pancreatic fistulas does not provide clinically significant benefit. | 1C | | Perussi Biscola et al [ 20 ] | 2017 | Systematic review | The new heterologous fibrin sealant from snake venom represents a consistent alternative to biological sealants, since they may avoid transmission of infectious diseases | 1C |
| Pommergaard et al [ 26 ] | 2013 | Systematic review | Liquid fibrin adhesive should be beneficial to prevent leak of ileal anastomoses in gastric and bariatric surgery | 1C |
| Saha et al [ 9 ] | 2012 | Prospective randomized | Fibrin sealant is safe and its efficacy is superior to manual compression for hemostasis in patients with vascular ePTFE graft | 1C |
| Schwartz et al [ 6 ] | 2004 | Prospective randomized controlled | Crosseal fibrin sealant significantly reduces the time of hemostasis following liver resection in comparison with the standard topical hemostatic agents | 1C |
| Simo et al [ 15 ] | 2012 | Systematic review | Application of TachoSil® in hepatobiliary and pancreatic surgery has proven effectiveness in hemostasis and as tissue sealant | 1C |
| Spotniz et al [ 7 ] | 2012 | Systematic review | Fibrin sealants have multiple new uses that should result in further improvement in patient care | 1C |
| Taylor et al[ 8 ] | 2003 | Randomized prospective multicenter | Fibrin sealants are more effective than thrombin-soaked gelatin sponge for achieving hemostasis of needle or suture hole bleeding from PTFE femoral artery grafts. | 1B |
| Vakalopoulos et al [ 25 ] | 2012 | Systematic review | Fibrin sealant seem not be necessary as external coating of colonic anastomoses to prevent leakage | 1C |
…”
Section: Results
mentioning
confidence: 99%
Abstract
Smart CitationsHow the paper below cites the one you are viewing
“…Fibrin glue and microsuturing primarily function as coaptation agents, securing nerve ends and facilitating axonal regeneration following nerve injury. 28 , 29 These materials are typically biocompatible and bioabsorbable, providing temporary mechanical support; however, their therapeutic effects may be impeded by scar tissue infiltration, which disrupts the favorable microenvironment required for optimal nerve healing and regeneration. The incorporation of biologics, including PRP and other growth factors, has attracted increasing interest due to their potential to modulate this microenvironment.…”
Section: Discussion
mentioning
confidence: 99%
Smart CitationsHow the paper below cites the one you are viewing
“…The two components usually contain added plasmatic proteins such as factor XIII, fibronectin, and an anti-fibrinolytic agent like aprotinin or tranexamic acid [ 7 ]. Nowadays, aprotinin-free and tranexamic acid-free formulations are available [ 3 , 5 ] reducing the risk of side effects, such as aprotinin-associated hypersensitivity reactions, and tranexamic acid-associated neurotoxicity [ 3 , 5 , 20 – 23 ]. Several adhesives are available as liquid formulations (Evicel®, Crosseal™, Quixil®, Floseal®, Surgiflo®, Tisseel®, Beriplast P®) or as medicated sponge/patch (Tachosil®, Evarrest®).…”
Section: Results
mentioning
confidence: 99%
“…Liquid fibrin adhesives are also effective as sealants, an adjunctive measure which improves the watertight closure of the dural suture line thus preventing cerebrospinal fluid leak (CSF) [ 20 – 23 ]. Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity.…”
Section: Results
mentioning
confidence: 99%
“…Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity. In fact, some evidence from preclinical studies has shown that tranexamic acid induced hyperexcitability and convulsions, probably caused by blocking GABA-mediated inhibition in the central nervous system [ 1 , 20 – 23 ].…”
Section: Results
mentioning
confidence: 99%
“…Routine use of TachoSil® patch to prevent pancreatic fistulas does not provide clinically significant benefit. | 1C | | Perussi Biscola et al [ 20 ] | 2017 | Systematic review | The new heterologous fibrin sealant from snake venom represents a consistent alternative to biological sealants, since they may avoid transmission of infectious diseases | 1C |
| Pommergaard et al [ 26 ] | 2013 | Systematic review | Liquid fibrin adhesive should be beneficial to prevent leak of ileal anastomoses in gastric and bariatric surgery | 1C |
| Saha et al [ 9 ] | 2012 | Prospective randomized | Fibrin sealant is safe and its efficacy is superior to manual compression for hemostasis in patients with vascular ePTFE graft | 1C |
| Schwartz et al [ 6 ] | 2004 | Prospective randomized controlled | Crosseal fibrin sealant significantly reduces the time of hemostasis following liver resection in comparison with the standard topical hemostatic agents | 1C |
| Simo et al [ 15 ] | 2012 | Systematic review | Application of TachoSil® in hepatobiliary and pancreatic surgery has proven effectiveness in hemostasis and as tissue sealant | 1C |
| Spotniz et al [ 7 ] | 2012 | Systematic review | Fibrin sealants have multiple new uses that should result in further improvement in patient care | 1C |
| Taylor et al[ 8 ] | 2003 | Randomized prospective multicenter | Fibrin sealants are more effective than thrombin-soaked gelatin sponge for achieving hemostasis of needle or suture hole bleeding from PTFE femoral artery grafts. | 1B |
| Vakalopoulos et al [ 25 ] | 2012 | Systematic review | Fibrin sealant seem not be necessary as external coating of colonic anastomoses to prevent leakage | 1C |
…”
Section: Results
mentioning
confidence: 99%
Abstract
Smart CitationsHow the paper below cites the one you are viewing
“…Fibrin glue and microsuturing primarily function as coaptation agents, securing nerve ends and facilitating axonal regeneration following nerve injury. 28 , 29 These materials are typically biocompatible and bioabsorbable, providing temporary mechanical support; however, their therapeutic effects may be impeded by scar tissue infiltration, which disrupts the favorable microenvironment required for optimal nerve healing and regeneration. The incorporation of biologics, including PRP and other growth factors, has attracted increasing interest due to their potential to modulate this microenvironment.…”
Section: Discussion
mentioning
confidence: 99%
Smart CitationsHow the paper below cites the one you are viewing
“…The two components usually contain added plasmatic proteins such as factor XIII, fibronectin, and an anti-fibrinolytic agent like aprotinin or tranexamic acid [ 7 ]. Nowadays, aprotinin-free and tranexamic acid-free formulations are available [ 3 , 5 ] reducing the risk of side effects, such as aprotinin-associated hypersensitivity reactions, and tranexamic acid-associated neurotoxicity [ 3 , 5 , 20 – 23 ]. Several adhesives are available as liquid formulations (Evicel®, Crosseal™, Quixil®, Floseal®, Surgiflo®, Tisseel®, Beriplast P®) or as medicated sponge/patch (Tachosil®, Evarrest®).…”
Section: Results
mentioning
confidence: 99%
“…Liquid fibrin adhesives are also effective as sealants, an adjunctive measure which improves the watertight closure of the dural suture line thus preventing cerebrospinal fluid leak (CSF) [ 20 – 23 ]. Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity.…”
Section: Results
mentioning
confidence: 99%
“…Nevertheless, cautions in using fibrin adhesive containing tranexamic acid in a neurosurgical setting is necessary, because of its neurotoxicity. In fact, some evidence from preclinical studies has shown that tranexamic acid induced hyperexcitability and convulsions, probably caused by blocking GABA-mediated inhibition in the central nervous system [ 1 , 20 – 23 ].…”
Section: Results
mentioning
confidence: 99%
“…Routine use of TachoSil® patch to prevent pancreatic fistulas does not provide clinically significant benefit. | 1C | | Perussi Biscola et al [ 20 ] | 2017 | Systematic review | The new heterologous fibrin sealant from snake venom represents a consistent alternative to biological sealants, since they may avoid transmission of infectious diseases | 1C |
| Pommergaard et al [ 26 ] | 2013 | Systematic review | Liquid fibrin adhesive should be beneficial to prevent leak of ileal anastomoses in gastric and bariatric surgery | 1C |
| Saha et al [ 9 ] | 2012 | Prospective randomized | Fibrin sealant is safe and its efficacy is superior to manual compression for hemostasis in patients with vascular ePTFE graft | 1C |
| Schwartz et al [ 6 ] | 2004 | Prospective randomized controlled | Crosseal fibrin sealant significantly reduces the time of hemostasis following liver resection in comparison with the standard topical hemostatic agents | 1C |
| Simo et al [ 15 ] | 2012 | Systematic review | Application of TachoSil® in hepatobiliary and pancreatic surgery has proven effectiveness in hemostasis and as tissue sealant | 1C |
| Spotniz et al [ 7 ] | 2012 | Systematic review | Fibrin sealants have multiple new uses that should result in further improvement in patient care | 1C |
| Taylor et al[ 8 ] | 2003 | Randomized prospective multicenter | Fibrin sealants are more effective than thrombin-soaked gelatin sponge for achieving hemostasis of needle or suture hole bleeding from PTFE femoral artery grafts. | 1B |
| Vakalopoulos et al [ 25 ] | 2012 | Systematic review | Fibrin sealant seem not be necessary as external coating of colonic anastomoses to prevent leakage | 1C |
…”
Section: Results
mentioning
confidence: 99%
Abstract
Smart CitationsHow the paper below cites the one you are viewing
“…Fibrin glue and microsuturing primarily function as coaptation agents, securing nerve ends and facilitating axonal regeneration following nerve injury. 28 , 29 These materials are typically biocompatible and bioabsorbable, providing temporary mechanical support; however, their therapeutic effects may be impeded by scar tissue infiltration, which disrupts the favorable microenvironment required for optimal nerve healing and regeneration. The incorporation of biologics, including PRP and other growth factors, has attracted increasing interest due to their potential to modulate this microenvironment.…”
Section: Discussion
mentioning
confidence: 99%