2014
DOI: 10.1109/jsen.2014.2323220
|View full text |Cite
|
Sign up to set email alerts
|

Multiparametric, Flexible Microsensor Platform for Metabolic Monitoring <inline-formula> <tex-math notation="TeX">\(In~Vivo\) </tex-math></inline-formula>

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
5
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 36 publications
(8 citation statements)
references
References 18 publications
2
5
0
Order By: Relevance
“…The polyurethane membrane is required to extend the linear range, which is critical for lactate measurement considering the low apparent K M of LOx 33 . Coherently, polyurethane promoted a significant increase in K M both for lactate (from 1.4 ± 0.2 mM to 22 ± 6 mM, unpublished) and glucose (from 6.6 ± 0.2 mM 29 to 80 ± 14 mM), in accordance to data reported by others 16, 30, 32 . This effect is consequence of the diffusion limitation of analyte versus O 2 imposed by the polyurethane layer and unlikely due to an actual change in enzyme kinetics.…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…The polyurethane membrane is required to extend the linear range, which is critical for lactate measurement considering the low apparent K M of LOx 33 . Coherently, polyurethane promoted a significant increase in K M both for lactate (from 1.4 ± 0.2 mM to 22 ± 6 mM, unpublished) and glucose (from 6.6 ± 0.2 mM 29 to 80 ± 14 mM), in accordance to data reported by others 16, 30, 32 . This effect is consequence of the diffusion limitation of analyte versus O 2 imposed by the polyurethane layer and unlikely due to an actual change in enzyme kinetics.…”
Section: Discussionsupporting
confidence: 90%
“…The detailed in vitro characterization revealed that the dual glucose and lactate oxidase- microbiosensor array, based on an efficient glutaraldehyde immobilization procedure following polyurethane coating, exhibit suitable analytical performance towards measurements in brain tissue, in particular a good linear range, high sensitivity and selectivity. In particular the sensitivity and linear range are comparable with data previously reported for planar microbiosensors 30, 31 and Pt-wire-based microbionsensors 32 similarly modified with phenylenediamines and polyurethane. The polyurethane membrane is required to extend the linear range, which is critical for lactate measurement considering the low apparent K M of LOx 33 .…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…In addition, since perm -elective membranes are often deposited by spin coating, the membrane pore size and thickness are difficult to control [6]. Chemical interference by other species that can be oxidized or reduced is also problematic during oxidoreductase-based biosensing of alcohols, phenols, sugars, and metabolic intermediates by amperometric monitoring of either O 2 depletion or H 2 O 2 formation [7][8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Here we report an amperometric Bioelectronic Tongue that contains enzyme electrodes for determination of glucose ascorbic acid, uric acid, and acetaminophen in controlled mixtures, and compare the response of individual sensors with the pattern response of the entire array. While others have reported electrode arrays that include multiple oxidoreductase enzymes, they have analyzed only the individual electrode responses, not the collective array response [7,8,11,12].…”
Section: Introductionmentioning
confidence: 99%