2019
DOI: 10.1021/acs.macromol.9b01996
|View full text |Cite
|
Sign up to set email alerts
|

Multimechanophore Graft Polymers: Mechanochemical Reactions at Backbone–Arm Junctions

Abstract: Typical multimechanophore polymers (MMPs) are comprised of numerous mechanophores (force-responsive moieties) distributed throughout the backbone of linear polymers. We have developed a new MMP design based on graft polymers with mechanophores linking each arm to the backbone. By utilizing maleimide–anthracene cycloadducts, polymeric species containing anthracene were released from the parent polymer, enabling facile quantification of mechanophore activation. With pulsed ultrasound experiments, we observed tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
68
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 39 publications
(72 citation statements)
references
References 82 publications
3
68
0
Order By: Relevance
“…Bottlebrush polymers (P-PS and P-PLA)and dendronized polymers (P-eGX and P-FGX)w ere prepared with varying degrees of polymerization (DPs, Table 1). Linear poly(norbornene)-based polymers with benzyl side-chains (P-Bn from the monomer Bn)w ere also prepared to provide ab enchmark for comparisons.L astly,g raft MMPs were prepared from macromonomers (PS Xm and eG4 m )containing am aleimide-anthracene cycloadduct (a popular mechanophore) [38,45,65,66] located between the arm/dendron and norbornene units.F or brush polymers,t his MMP design pre-viously enabled efficient mechanophore activation. In total, 29 bottlebrush polymers,2 2d endronized polymers,a nd 4 linear polymers were synthesized.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Bottlebrush polymers (P-PS and P-PLA)and dendronized polymers (P-eGX and P-FGX)w ere prepared with varying degrees of polymerization (DPs, Table 1). Linear poly(norbornene)-based polymers with benzyl side-chains (P-Bn from the monomer Bn)w ere also prepared to provide ab enchmark for comparisons.L astly,g raft MMPs were prepared from macromonomers (PS Xm and eG4 m )containing am aleimide-anthracene cycloadduct (a popular mechanophore) [38,45,65,66] located between the arm/dendron and norbornene units.F or brush polymers,t his MMP design pre-viously enabled efficient mechanophore activation. In total, 29 bottlebrush polymers,2 2d endronized polymers,a nd 4 linear polymers were synthesized.…”
Section: Resultsmentioning
confidence: 99%
“…[16,17] Va rious design principles influence mechanochemical reactivity including the location of mechanophores, [18] regio-and stereochemistry, [19][20][21][22][23] linkers, [24][25][26] polymer composition, [27,28] and polymer topology. [29] In regard to topology,i ntramolecularly cross-linked, [30][31][32][33][34] cyclic, [35] dendritic, [36,37] star, [38][39][40][41][42][43] bottlebrush, [44][45][46] and dendronized polymers, [47] have been utilized to tune mechanochemical reaction kinetics and/or mechanophore activation efficiency. Them ajority of these topology studies have been conducted using ultrasonication (US) or, to alesser extent, ball-mill grinding (BMG).…”
Section: Introductionmentioning
confidence: 99%
“…In our polymers, the mechanophores were confined to the side‐chains in the proximity of the branch points. We chose comb polymers to maximize the efficiency of transducing external mechanical load to the force acting on individual mechanophores [45, 46] . Doing so is expected to reduce the minimum concentration of mechanophores needed to elicit a detectable stress response, which is critical for practical applications of such polymers.…”
Section: Methodsmentioning
confidence: 99%
“…9 Degradation studies were conducted as previously described. 10,11 In short, an Arpurged solution of polymer in inhibitor-free, HPLC-grade THF (15 mg of polymer at 1 mg/mL concentration) was prepared in a sealed Suslick flask under Ar atmosphere. The Suslick flask was submerged in a cold bath (maintained at -10 ˚ C by a recirculating chiller) and the polymer solutions was sonicated at 16.9 W/cm 2 using a pulse sequence of 1 s "on", 4 s "off".…”
Section: Polymer Degradation Studies and Analysismentioning
confidence: 99%