Motion-insensitive optical coherence tomography based micro-angiography

Abstract: An improved image processing procedure for suppressing the phase noise due to a motion artifact acquired during optical coherence tomography scanning and effectively illustrating the blood vessel distribution in a living tissue is demonstrated. This new processing procedure and the widely used procedure for micro-angiography application are based on the selection of high-frequency components in the spatial-frequency spectrum of B-mode scanning (x-space), which are contributed from the image portions of moving … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2015
2015

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…The used OCT system is built based on a swept source OCT configuration, as schematically shown in Fig. 2a [21]. Here, the swept source has a sweeping wavelength range of 170 nm (Santec, HSL2100).…”
Section: Ample Preparation and Experimental Setupmentioning
confidence: 99%
“…The used OCT system is built based on a swept source OCT configuration, as schematically shown in Fig. 2a [21]. Here, the swept source has a sweeping wavelength range of 170 nm (Santec, HSL2100).…”
Section: Ample Preparation and Experimental Setupmentioning
confidence: 99%
“…23 The power Doppler OCT and/or optical angiography/microangiography (OMAG) are other imaging techniques based on the Doppler effect that is able to isolate blood flow signals from the static tissue background. [24][25][26][27][28][29][30][31][32][33][34][35][36] This method does not allow visualization of flow velocity directly; it provides a measure of the total backscattered optical signal attributable to moving targets with higher SNR 37 compared to DOCT. Unlike phase-based approaches, OMAG directly analyzes and processes an image, which can minimize the phase instability noise.…”
Section: Introductionmentioning
confidence: 99%
“…If you take a photo of a flying ball, the blur on the picture is a demonstration of this type of motion artifacts. Since this kind of artifacts is prevailing in biomedical applications, several approaches to solving the motion artifacts have already been published [57]. …”
Section: Introductionmentioning
confidence: 99%