2012
DOI: 10.1167/iovs.11-9142
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring of Cornea Elastic Properties Changes during UV-A/Riboflavin-Induced Corneal Collagen Cross-Linking using Supersonic Shear Wave Imaging: A Pilot Study

Abstract: The in vivo CXL experiments performed on pigs demonstrated that the quantitative estimation of local stiffness and the 2-D elastic maps of the corneal surface provide an efficient way to monitor the local efficacy of corneal cross-linking.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
40
1

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(46 citation statements)
references
References 12 publications
5
40
1
Order By: Relevance
“…Curve fitting of the radial profile at 310 Hz ( Fig. 5(a) [24]. To validate our observation, we performed a finite element (FE) numerical simulation [25].…”
Section: Resultsmentioning
confidence: 65%
“…Curve fitting of the radial profile at 310 Hz ( Fig. 5(a) [24]. To validate our observation, we performed a finite element (FE) numerical simulation [25].…”
Section: Resultsmentioning
confidence: 65%
“…Previous studies on corneas using ultrasound elastography did not take into account the influence of the corneal curvature on the spatial mapping of the corneal stiffness with the Lamb wave velocity [13][14][15]. Corneal curvature could have an effect on the depthwise distribution of the Lamb wave velocity.…”
Section: Discussionmentioning
confidence: 99%
“…After getting the displacement profiles for all the transverse-depthwise positions of the cornea, a binarized two-dimensional depth-resolved OCT image is used as a mask to eliminate the spatial points with random optical phase information. Because the corneal Lamb wave propagation is guided by the surface of the cornea, similar to the ultrasound elastography of the cornea [13][14][15], the quantification of the Lamb wave phase velocity is based on the curved propagation paths that have the same curvature as the corneal surface. As the example to present our method for corneal elastography, Fig.…”
Section: Data Processingmentioning
confidence: 99%
See 1 more Smart Citation
“…4 OCE is similar to other elastographic techniques such as ultrasound elastography (USE), 5 magnetic resonance elastography (MRE), 6 and supersonic shear wave imaging (SSI) [7][8][9] where an externally induced deformation is measured by the respective imaging modality. OCE has micrometer scale spatial resolution 10 and millisecond temporal resolution but has a limited penetration depth of a few millimeters in scattering media such as tissue.…”
mentioning
confidence: 99%