2017
DOI: 10.4172/2155-9872.1000359
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring Glycosylation Profile and Protein Titer in Cell Culture Samples Using ZipChip CE-MS

Abstract: Rapid and sensitive product quality analysis is important for real-time monitoring during biopharmaceutical development and manufacturing. However, low level of protein concentration and complex cell culture matrix pose challenges for product quality characterization at early stages of cell line selection and process development. Here, we describe a fast and simple microfluidic ZipChip CE-MS method to measure quality attributes of monoclonal antibody protein directly from cell culture supernatant. Cell culture… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(31 citation statements)
references
References 16 publications
0
31
0
Order By: Relevance
“…The ZipChip system was operated according to manufacturer protocol for high resolution separation as previously described 15 . Briefly, the device was positioned on the inlet of a Q Exactive HF (Thermo).…”
Section: Methodsmentioning
confidence: 99%
“…The ZipChip system was operated according to manufacturer protocol for high resolution separation as previously described 15 . Briefly, the device was positioned on the inlet of a Q Exactive HF (Thermo).…”
Section: Methodsmentioning
confidence: 99%
“…[2][3][4] The main objective is to real time monitor the concentrations of some process parameters, such as viable cell, nutrient, and metabolite concentrations, whose variability may have an impact on mAb quality attributes. [10][11][12] Moreover, delays due to off-line analysis may also compromise real time control of the process. [6][7][8] Therefore, its control is essential to ensure efficacy of the product and safety for patients.…”
Section: Introductionmentioning
confidence: 99%
“…9 Even in advanced production processes supporting the PAT initiative, glycosylationmonitoring still requires some sample handling through the semiautomatic off-line analysis. [10][11][12] Moreover, delays due to off-line analysis may also compromise real time control of the process. A new challenging objective for PAT is thus to control mAb glycosylation as well as cell metabolism using online spectroscopy.…”
Section: Introductionmentioning
confidence: 99%
“…and Zang et al. . In utilization of the HR variety chip, intact antibodies have been analyzed as well as viral capsid proteins by Chen et al.…”
Section: Introductionmentioning
confidence: 99%