1998
DOI: 10.1002/(sici)1099-0801(199805/06)12:3<155::aid-bmc793>3.0.co;2-r
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Miniaturized thermal lens device for capillary electrophoresis

Abstract: In this paper we will report on the combination of a miniaturized fiber optic modified photothermal sensor (size 2 × 2× 2 cm) to capillary electrophoresis (CE) as detection device. The properties and the performances of the thermal lens detector, based on a double beam absorption scheme, were studied in a capillary electrophoresis system with different types of toxic pollutants, e.g. pesticides. A tunable Argon ion laser, which emits between 364 and 514 nm, was adapted to a commercial injection and high voltag… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
13
1
1
1

Citation Types

1
8
0
0

Year Published

1998
1998
2022
2022

Publication Types

Select...
12
2

Relationship

0
14

Authors

Journals

citations

Cited by 14 publications

(9 citation statements)
references

References 4 publications

1
8
0
0
Order By: Relevance
How this paper cites the one you are viewing
“…4, is 0.5 lM, which is below the values previously reported for thermal-lens detection in CZE under similar detection condi- tions. 4,6,7,12,14,18,19 The detection limit for the ''central'' configuration and for the conventional UV-Vis detection scheme is 6 lM. Thus, the ratio between detection limits achieved for ''marginal'' and ''central'' configurations is in perfect agreement with the sensitivity enhancement calculated in the previous section.…”
Section: Results
supporting
confidence: 80%
“…5); the increase in the sensitivity (Table I) is in accordance with the expected value. 12 Thermal-lens detection of the 4-aminoazobenzene zone passing through the detection window results in a peak of an unusual shape compared to that obtained by UV-Vis detection (compare Figs. 4E and 4F).…”
Section: Results
mentioning
confidence: 97%
“…1), a schematic proved advantageous for photothermal detection in combination with capillary electrophoresis. 12,22,23 For the excitation, a He-Cd laser is used (excitation wavelength, k e , 325 nm, IK3552R-G Kimmon Electronic Co., Ltd. Tokyo, Japan). The laser power in the sample P e is 50 mW, and spot size at the waist is 7.7 lm.…”
Section: Methods
mentioning
confidence: 99%
“…Crossed-beam photothermal-lens (thermal-lens) spectrometry (TLS) 1,2 is a reliable and sensitive detection technique for stateof-the-art capillary zone electrophoresis (CZE) [3][4][5][6][7][8][9][10][11][12] and has many applications. 6,[10][11][12][13][14][15][16][17] It provides a drastic increase in sensitivity compared to the conventional ultraviolet-visible (UV-Vis) detection for various analytes.…”
Section: Introduction
mentioning
confidence: 99%
See 3 more Smart Citations
How this paper cites the one you are viewing
“…4, is 0.5 lM, which is below the values previously reported for thermal-lens detection in CZE under similar detection condi- tions. 4,6,7,12,14,18,19 The detection limit for the ''central'' configuration and for the conventional UV-Vis detection scheme is 6 lM. Thus, the ratio between detection limits achieved for ''marginal'' and ''central'' configurations is in perfect agreement with the sensitivity enhancement calculated in the previous section.…”
Section: Results
supporting
confidence: 80%
“…5); the increase in the sensitivity (Table I) is in accordance with the expected value. 12 Thermal-lens detection of the 4-aminoazobenzene zone passing through the detection window results in a peak of an unusual shape compared to that obtained by UV-Vis detection (compare Figs. 4E and 4F).…”
Section: Results
mentioning
confidence: 97%
“…1), a schematic proved advantageous for photothermal detection in combination with capillary electrophoresis. 12,22,23 For the excitation, a He-Cd laser is used (excitation wavelength, k e , 325 nm, IK3552R-G Kimmon Electronic Co., Ltd. Tokyo, Japan). The laser power in the sample P e is 50 mW, and spot size at the waist is 7.7 lm.…”
Section: Methods
mentioning
confidence: 99%
“…Crossed-beam photothermal-lens (thermal-lens) spectrometry (TLS) 1,2 is a reliable and sensitive detection technique for stateof-the-art capillary zone electrophoresis (CZE) [3][4][5][6][7][8][9][10][11][12] and has many applications. 6,[10][11][12][13][14][15][16][17] It provides a drastic increase in sensitivity compared to the conventional ultraviolet-visible (UV-Vis) detection for various analytes.…”
Section: Introduction
mentioning
confidence: 99%
See 2 more Smart Citations
How this paper cites the one you are viewing
“……”
Section: Ic-tls and Ce-tls
mentioning
confidence: 99%