2002
DOI: 10.1002/1521-4109(200208)14:14<989::aid-elan989>3.0.co;2-6
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized Reference Electrodes Based on Ag/AgiX Internal Reference Elements. I. Manufacturing and Performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
32
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(33 citation statements)
references
References 14 publications
0
32
0
Order By: Relevance
“…The working electrode was a freshly polished platinum disk (0.03 cm 2 active area), the counter electrode was a platinum wire, and the reference electrode was a Ag/ AgCl miniaturized reference electrode (MRE) fabricated according to literature procedures [39]. Prior to measurement, the working electrode was polished with alumina, sonicated in deionized water, and rinsed with n-butanol, and the reference electrode was conditioned in the electrolyte (0.1 LiClO 4 in n-butanol) for 10 min.…”
Section: Full Papermentioning
confidence: 99%
“…The working electrode was a freshly polished platinum disk (0.03 cm 2 active area), the counter electrode was a platinum wire, and the reference electrode was a Ag/ AgCl miniaturized reference electrode (MRE) fabricated according to literature procedures [39]. Prior to measurement, the working electrode was polished with alumina, sonicated in deionized water, and rinsed with n-butanol, and the reference electrode was conditioned in the electrolyte (0.1 LiClO 4 in n-butanol) for 10 min.…”
Section: Full Papermentioning
confidence: 99%
“…It is well known that the most common reference electrodes are based on calomel, on sulfates and on Ag/AgCl, where the latter clearly exhibit superior characteristics regarding the miniaturization possibilities [6][7][8][9][10]. The use of polymers [11][12][13][14][15], membranes [16] instead of water to immobilize the chloride ions. Recently MnO 2 were reported as a best sensor electrode in concrete environments [17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, various non-silicon-based (e.g. conventional glass tube-based and PDMS-based) miniaturized reference electrodes (MREs) have been continuously developed in the last decade and performed very good electrochemical characteristics [9][10][11][12][13][14][15][16][17]. The physical size of MREs is about tenfold more than that of JlREs and their fabrication processes are not compatible with the silicon-based microfabrication technology, which limits their integration with electronic circuits and the development of system-on-a-chip (SOC).…”
Section: Introductionmentioning
confidence: 99%