2001
DOI: 10.1006/abio.2001.4991
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturization of a Hepatitis C Virus RNA Polymerase Assay Using a −102°C Cooled CCD Camera-Based Imaging System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
15
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 11 publications
0
15
0
Order By: Relevance
“…SPA beads are available in PVT or YSi for the PMT-based readers and in PS or YOx for the CCD-based readers. Although yttrium-based beads have a higher sensitivity, 57,74 55 Wang et al 56 Zheng et al 57 Glycogen synthase kinase 68,74 In many cases the bead sensitivity is not an issue for assay development, and PS or PVT beads can be used more easily. A major cause of low sensitivity can be the background caused by unspecific binding of radiolabeled reagents to the beads, combined with low expression level of receptor or low enzyme turnover, and these issues cannot always be surmounted with the use of yttrium-based scintillants.…”
Section: Scintillation Materialsmentioning
confidence: 98%
See 2 more Smart Citations
“…SPA beads are available in PVT or YSi for the PMT-based readers and in PS or YOx for the CCD-based readers. Although yttrium-based beads have a higher sensitivity, 57,74 55 Wang et al 56 Zheng et al 57 Glycogen synthase kinase 68,74 In many cases the bead sensitivity is not an issue for assay development, and PS or PVT beads can be used more easily. A major cause of low sensitivity can be the background caused by unspecific binding of radiolabeled reagents to the beads, combined with low expression level of receptor or low enzyme turnover, and these issues cannot always be surmounted with the use of yttrium-based scintillants.…”
Section: Scintillation Materialsmentioning
confidence: 98%
“…57,89,90 First, because the CCD imagers collected a digital "photograph" of the entire MTP, all of the wells were read simultaneously, with an exposure time of about 2 min. These instruments' software is used to quantify the brightness of emission from each well (see Fig.…”
Section: Scintillation Readersmentioning
confidence: 99%
See 1 more Smart Citation
“…Other accessory replication proteins involved in the process of both leading-and lagging-strand DNA synthesis may also be incorporated into this system, thus further increasing its usefulness for the identification of antagonists of the DNA replication machine. Last, most scintillation proximity assays monitoring polymerase activity use biotinylated nucleotide substrates (13,14), followed by capture onto streptavidin-coated SPA beads. In this assay unmodified substrates may be used, eliminating any confounding factors associated with using nonnatural substrates.…”
Section: Specificity For Dnag Primasementioning
confidence: 99%
“…The first-generation LEADseeker platform, the radiometric LEADseeker, has already demonstrated the benefits that imaging offers over conventional PMT-based systems for radioactive-based screening. 14 Here, in addition to comparing fluorophore/quencher pairs, we assess the potential advantages that imaging provides over PMT-based detection systems for fluorescence-based HTS protease assays.…”
mentioning
confidence: 99%