1986
DOI: 10.1021/ac00294a026
|View full text |Cite
|
Sign up to set email alerts
|

Micrometer-spaced platinum interdigitated array electrode: fabrication, theory, and initial use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
112
0

Year Published

1989
1989
2014
2014

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 214 publications
(114 citation statements)
references
References 41 publications
2
112
0
Order By: Relevance
“…Paired microbands have been developed by an epoxied thin mica sheet with sputtered gold on both sides [11] or by sealing of two metalized glass slides separated with a plastic spacer [12] . Photolithography has also been employed to fabricate microbands [13][14][15] and interdigited array electrodes [16] by metal evaporation [17] , sputtering [18,19] and chemical vapour deposition [7,20,21] . Boron doped diamond ultramicroband electrodes have been realised based on lithography and chemical vapour deposition [22,23] .…”
Section: Introductionmentioning
confidence: 99%
“…Paired microbands have been developed by an epoxied thin mica sheet with sputtered gold on both sides [11] or by sealing of two metalized glass slides separated with a plastic spacer [12] . Photolithography has also been employed to fabricate microbands [13][14][15] and interdigited array electrodes [16] by metal evaporation [17] , sputtering [18,19] and chemical vapour deposition [7,20,21] . Boron doped diamond ultramicroband electrodes have been realised based on lithography and chemical vapour deposition [22,23] .…”
Section: Introductionmentioning
confidence: 99%
“…Unlike RRDEs, no rotation is required in IDAs, and the reaction with oxygen and the detection of PROS are diffusion-limited processes. IDAs have previously been used (11)(12)(13)(14) to assess the formation of PROS with reduction catalysts (13). The study presents here a report of the detection of PROS on IDAs as a function of eT through SAMs functionalized with hemoprotein models.…”
mentioning
confidence: 99%
“…However, this technique has limited collection efficiencies (CE, i.e., percentage of the PROS generated being detected on the ring). Interdigitated array (IDA) Electrodes provide an alternative to rotating ring disc techniques for detecting products/byproducts of unstirred electrochemical reactions (40). IDAs have 2 sets of alternate arrays of electrodes (10 m wide) spaced 5-10 m apart (Fig.…”
mentioning
confidence: 99%