2018
DOI: 10.3791/58455
|View full text |Cite
|
Sign up to set email alerts
|

Microdialysis of Excitatory Amino Acids During EEG Recordings in Freely Moving Rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Most studies performed in rodent models have not captured such physically coincident analyte and electrophysiological data. The setups that successfully collected neurochemical data and electrophysiology data from the same probe employed small-molecule microdialysis and targeted neurotransmitters such as GABA and glutamate and other amino acids [115,[119][120][121] with improved spatial resolution [115]. These preclinical setups did collect relatively coincident data correlating neurotransmitters to seizure activity but were limited by the lack of sensitivity to large compounds due to the nature of microdialysis.…”
Section: Discussion and Open Challengesmentioning
confidence: 99%
See 2 more Smart Citations
“…Most studies performed in rodent models have not captured such physically coincident analyte and electrophysiological data. The setups that successfully collected neurochemical data and electrophysiology data from the same probe employed small-molecule microdialysis and targeted neurotransmitters such as GABA and glutamate and other amino acids [115,[119][120][121] with improved spatial resolution [115]. These preclinical setups did collect relatively coincident data correlating neurotransmitters to seizure activity but were limited by the lack of sensitivity to large compounds due to the nature of microdialysis.…”
Section: Discussion and Open Challengesmentioning
confidence: 99%
“…Some of the more elementary designs involve two separate probes for neurochemical sampling and EEG recording [95,96,102,104,[106][107][108][109][110][111][112][113][114]. Other designs successfully incorporate both technologies into a single probe [98][99][100][101]103] or even fix separate probes together through various means [115][116][117][118][119][120][121]. The majority of these studies were conducted in vitro or in non-human animal models, with minimal evidence obtained from clinical studies to date [122,123].…”
Section: Previously Fabricated Microdialysis and Microperfusion Electrode Systemsmentioning
confidence: 99%
See 1 more Smart Citation