2017
DOI: 10.1016/j.ultrasmedbio.2016.09.007
|View full text |Cite
|
Sign up to set email alerts
|

Metrological Validation of a Measurement Procedure for the Characterization of a Biological Ultrasound Tissue-Mimicking Material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 22 publications
1
7
0
Order By: Relevance
“…The mean SoS of the B control was found to be 1536.6 ± 2.0 ms -1 . The SoS was found to be in good agreement with those studies published of the acoustic properties of IEC agar-TMM acoustics (Brewin et al, 2008;Browne et al, 2003;Rabell Montiel et al, 2017b;Rajagopal et al, 2014;Santos et al, 2017, Sun et al, 2012 and falls within the IEC recommended guideline (IEC, 2001).…”
Section: Discussionsupporting
confidence: 87%
See 2 more Smart Citations
“…The mean SoS of the B control was found to be 1536.6 ± 2.0 ms -1 . The SoS was found to be in good agreement with those studies published of the acoustic properties of IEC agar-TMM acoustics (Brewin et al, 2008;Browne et al, 2003;Rabell Montiel et al, 2017b;Rajagopal et al, 2014;Santos et al, 2017, Sun et al, 2012 and falls within the IEC recommended guideline (IEC, 2001).…”
Section: Discussionsupporting
confidence: 87%
“…-The second document (10.1016/j.ultrasmedbio.2016.09.007) cited corresponds to studies of 10 mm and 20 mm thick samples of TMM. This document has been cited as Santos et al, 2017. The method used to collect the data was using two operators and an interval between subsequent measurements, in a similar manner to that employed by Rajagopal et al, (2014).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The ultrasonic properties of materials within the megahertz frequency range are determined using techniques commonly referred to as the through-transmission substitution technique [42,43] and as pulse-echo technique [44]. Using those techniques, it is possible to measure speed of sound and attenuation coefficient of the material under text.…”
Section: Ultrasound Parameter Measurementmentioning
confidence: 99%
“…For inspection in liquid media, the most important aspects are the ultrasonic phase velocity and the scattering pattern [42,43,45]. The behavior of those derived quantities as function of frequency is deeply related to density and viscosity.…”
Section: The Futurementioning
confidence: 99%