2021 28th National and 6th International Iranian Conference on Biomedical Engineering (ICBME) 2021
DOI: 10.1109/icbme54433.2021.9750327
|View full text |Cite
|
Sign up to set email alerts
|

Medial-lateral position of hand changes shoulder muscle synergy during the push-up exercises

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 28 publications
0
0
0
Order By: Relevance
“…Ten Vicon motion-capturing systems (Vicon MX, Oxford, UK, 100 Hz) were used to record kinematics data [15]. Motion analysis of push-up exercises allowed us to detect the angles [15,16]. The EMG activity in the anterior deltoid, middle deltoid, posterior deltoid, infraspinatus, upper pectoralis major, middle pectoralis major, lower pectoralis major, latissimus dorsi, triceps lateral, triceps medial, biceps brachii, upper trapezius, middle trapezius, and lower trapezius muscles was measured by a 14-channel wireless Myon EMG system (made in Switzerland) with a sampling frequency of 1000 Hz, as shown in Figure 1 [17].…”
Section: Instrumentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ten Vicon motion-capturing systems (Vicon MX, Oxford, UK, 100 Hz) were used to record kinematics data [15]. Motion analysis of push-up exercises allowed us to detect the angles [15,16]. The EMG activity in the anterior deltoid, middle deltoid, posterior deltoid, infraspinatus, upper pectoralis major, middle pectoralis major, lower pectoralis major, latissimus dorsi, triceps lateral, triceps medial, biceps brachii, upper trapezius, middle trapezius, and lower trapezius muscles was measured by a 14-channel wireless Myon EMG system (made in Switzerland) with a sampling frequency of 1000 Hz, as shown in Figure 1 [17].…”
Section: Instrumentsmentioning
confidence: 99%
“…Skin shaving and cleaning with alcohol were performed to reduce errors. The surface electrodes included self-adhesive with Ag/AgCl [16,19]. The surface reflective marker and EMG electrode placement for 14 muscles: anterior deltoid, middle deltoid, posterior deltoid, infraspinatus, upper pectoralis major, middle pectoralis major, lower pectoralis major, latissimus dorsi, triceps lateral, triceps medial, biceps brachii, upper trapezius, middle trapezius, and lower trapezius muscles in the motion analysis lab with ten high-speed motion Vicon cameras (Vicon Industries Ltd., Hampshire, UK).…”
Section: Instrumentsmentioning
confidence: 99%