Order By: Relevance
“…The formation mechanism of rain-wind induced vibration on the high-voltage conductor can be summarized by the following steps ( Figure 1) [3,7,11].…”
Section: Formation Mechanism Of Rain-wind Induced Vibration On the Himentioning
confidence: 99%
See 2 more Smart Citations
“…The formation mechanism of rain-wind induced vibration on the high-voltage conductor can be summarized by the following steps ( Figure 1) [3,7,11].…”
Section: Formation Mechanism Of Rain-wind Induced Vibration On the Himentioning
confidence: 99%
“…The asymmetric crosssection of the high-voltage conductor, motion of the rivulets, and time varying-mass of the whole system maybe are the main cause of rain-wind induced vibration on high-voltage transmission lines. Like the effect of icing galloping, this phenomenon can result in fatigue fractures of high-voltage conductor and fatigue failures of spacers and insulators and threaten the safety and serviceability of the high-voltage transmission tower-lines [2][3][4]. However, it is difficult to explain this phenomenon by Den.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Li [3,4] takes rainfall as a shock load to combine with wind turbulence and proposes a calculation method for the combination of rain excitation with wind force. Zhou [5][6][7] investigates the effects of ionic wind, rainfalls, and nonlinear cross-sections on the vibration amplitude of the high-voltage transmission line. However, few works on the effects of rivulet motion, electric field strength, and wind velocity for the mechanism of this vibration are carried out.…”
Section: Introductionmentioning
confidence: 99%
“…As transmission voltages of High-Voltage Alternating Current (HVAC) as well as HVDC transmission lines increase, corona discharge becomes a design factor, not only because of corona losses and their impact on efficiency of power transmission, but also due to the electromagnetic interference (EMI) caused to broadcast [1][2][3][4][5]. Moreover, the corona-generated ions produced by high-voltage transmission lines may affect health by enhancing exposure to aerosol pollutants [6].…”
Section: Introductionmentioning